An Entropy-Statistical Analysis of a Natural Gas Liquefaction Plant with External Nitrogen Cooling Cycle
- Авторы: Arkharov A.M.1, Semenov V.Y.1, Krasnonosova S.D.1
-
Учреждения:
- Bauman Moscow State Technical University
- Выпуск: Том 51, № 11-12 (2016)
- Страницы: 725-735
- Раздел: Research, Design, Calculations, and Operating Experience
- URL: https://ogarev-online.ru/0009-2355/article/view/234249
- DOI: https://doi.org/10.1007/s10556-016-0113-9
- ID: 234249
Цитировать
Аннотация
An entropy-statistical analysis of a 7 tons/h capacity small-tonnage CNG plant functioning in a cycle with external nitrogen expansion cooling demonstrated a probable value of the magnitude of thermodynamic perfection of 33%. Application of a rational multi-stage scheme with pre-cooling and the use of a compressor with isothermal efficiency 0.65 and turbine expansion engine with adiabatic efficiency 0.835 are responsible for the decisive contribution to achieving an increase in efficiency.
Об авторах
A. Arkharov
Bauman Moscow State Technical University
Email: v.semyonov1959@gmail.com
Россия, Moscow
V. Semenov
Bauman Moscow State Technical University
Автор, ответственный за переписку.
Email: v.semyonov1959@gmail.com
Россия, Moscow
S. Krasnonosova
Bauman Moscow State Technical University
Email: v.semyonov1959@gmail.com
Россия, Moscow
Дополнительные файлы