An Entropy-Statistical Analysis of a Natural Gas Liquefaction Plant with External Nitrogen Cooling Cycle
- Autores: Arkharov A.M.1, Semenov V.Y.1, Krasnonosova S.D.1
-
Afiliações:
- Bauman Moscow State Technical University
- Edição: Volume 51, Nº 11-12 (2016)
- Páginas: 725-735
- Seção: Research, Design, Calculations, and Operating Experience
- URL: https://ogarev-online.ru/0009-2355/article/view/234249
- DOI: https://doi.org/10.1007/s10556-016-0113-9
- ID: 234249
Citar
Resumo
An entropy-statistical analysis of a 7 tons/h capacity small-tonnage CNG plant functioning in a cycle with external nitrogen expansion cooling demonstrated a probable value of the magnitude of thermodynamic perfection of 33%. Application of a rational multi-stage scheme with pre-cooling and the use of a compressor with isothermal efficiency 0.65 and turbine expansion engine with adiabatic efficiency 0.835 are responsible for the decisive contribution to achieving an increase in efficiency.