TOPOGRAPHIC AND ANATOMICAL APPROACHES TO THE DEVELOPMENT OF THE PROTECTION SYSTEM OF THE POPLITEAL ARTERY DURING ARTHROSCOPIC POSTERIOR CRUCIATE LIGAMENT PLASTY


Cite item

Full Text

Abstract

The purpose of this study was to determine relationships between bone elements of the knee and popliteal artery. Type of study: anatomy and clinical. Materials and methods consist of 12 cadaveric knees, 14 MRI of the knee, 59 arteriograms of lower extremity 6 of cadaveric knees were x-rayed in the axial and sagittal planes at each of 3 flexion angles (180°, 130° and 90°) to determine the distance between posterior cruciate ligament and popliteal artery. During the study was also measured lengths of bone tunnels for arthroscopy posterior cruciate ligament reconstruction. Was fined, that in 100% of cases popliteal artery was in lateroposition (form 1 to 6 mm). The maximal distance between posterior cruciate ligament and popliteal artery were noted at flexion 90°. The length of the tibial tunnel was in a range from 63 to 78 cm, femoral - from 38 to 47 mm. Methods aimed at reducing risk of popliteal artery injury are offered.

About the authors

I. A. Kuznetsov

Vreden Russian Research Institute of Traumatology and Orthopedics

Author for correspondence.
Email: smithsport@mail.ru
Russian Federation

N. F. Fomin

Kirov Military Medical Academy

Email: fominmed@mail.ru
Russian Federation

D. A. Shulepov

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: shulepov@front.ru
Russian Federation

References

  1. Котельников Г.П. Посттравматическая нестабильность коленного сустава. Самара: Самарский дом печати; 1998. 184 с.
  2. Шилкин В.В., Филимонов В.И. Анатомия по Пирогову (атлас анатомии человека). М.: ГГЭОТАРМедиа; 2011. Т. 1. 600 с.
  3. Штробель М. Руководство по артроскопической хирургии. М.: Издательство Панфилова; 2012. Т. 1. 672 с.
  4. Ahn J.H., Wang J.H., Lee S.H., Yoo J.C., Jeon W.J. Increasing the distance between the posterior cruciate ligament and the popliteal neurovascular bundle by a limited posterior capsular release during arthroscopic transtibial posterior cruciate ligament reconstruction: a cadaveric angiographic study. Am. J. Sports Med. 2007; 35(5):787-792.
  5. Cohen S.B., Boyd L., Miller M.D. Vascular risk associated with posterior cruciate ligament reconstruction using the arthroscopic transtibial tunnel technique. J. Knee Surg. 2004;17(4):211-213.
  6. Cosgarea A.J., Kramer D.E., Bahk M.S., Totty W.G., Matava M.J. Proximity of the popliteal artery to the PCL during simulated knee arthroscopy: implications for establishing the posterior trans-septal portal. J. Knee Surg. 2006;19(3):181-185.
  7. Houe T., Jorgensen U. Arthroscopic posterior cruciate ligament reconstruction: one- vs. two-tunnel technique. Scand. J. Med. Sci. Sports. 2004;14(2):107-111.
  8. Keser S., Savranlar A., Bayar A., Ulukent S.C., Ozer T., Tuncay I. Anatomic localization of the popliteal artery at the level of the knee joint: a magnetic resonance imaging study. Arthroscopy. 2006;22(6):656-659.
  9. MacGillivray J.D., Stein B.E., Park M., Allen A.A., Wickiewicz T.L., Warren R.F. Comparison of tibial inlay versus transtibial techniques for isolated posterior cruciate ligament reconstruction: minimum 2-year follow-up. Arthroscopy. 2006;22(3):320-328.
  10. Makino A., Costa-Paz M., Aponte-Tinao L., Ayerza M.A., Muscolo D.L. Popliteal artery laceration during arthroscopic posterior cruciate ligament reconstruction. Arthroscopy. 2005;21(11):1396.
  11. McAllister D.R., Petrigliano F.A. Diagnosis and treatment of posterior cruciate ligament injuries. Curr. Sports Med. Rep. 2007;6(5):293-299.
  12. McKeon B.P., Bono J.V., Richmond J.C. Knee Arthroscopy. Springer; 2009. 578 p.
  13. Pace J.L., Wahl C.J. Arthroscopy of the posterior knee compartments: neurovascular anatomic relationships during arthroscopic transverse capsulotomy. Arthroscopy. 2010;26(5):637-642.
  14. Seon J.K., Song E.K. Reconstruction of isolated posterior cruciate ligament injuries: a clinical comparison of the transtibial and tibial inlay techniques. Arthroscopy. 2006;22(1):27-32.
  15. Yoo J.H., Chang C.B. The location of the popliteal artery in extension and 90 degree knee flexion measured on MRI. Knee. 2009;16(2):143-148.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2023 Traumatology and Orthopedics of Russia

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».