Analysis of the Tesla transformer operation at the first half-wave of the output voltage taking into account ohmic losses
- Autores: Palchikov E.I.1,2, Ryabchun A.M.1,2
-
Afiliações:
- Lavrentyev Institute of Hydrodynamics, Siberian Branch
- Novosibirsk State University
- Edição: Volume 61, Nº 6 (2016)
- Páginas: 919-923
- Seção: Electrophysics, Electron and Ion Beams, Physics of Accelerators
- URL: https://ogarev-online.ru/1063-7842/article/view/197380
- DOI: https://doi.org/10.1134/S1063784216060165
- ID: 197380
Citar
Resumo
The speed and efficiency of the Tesla transformer at the first half-wave of the output voltage are studied as a function of the Q factors of the circuits and their coupling factor. Calculated results and experimental data are considered. It is shown that for given Q factors, there is an optimal value of the coupling factor providing the highest efficiency, which can be calculated and for which designers should work.