Analysis of the Tesla transformer operation at the first half-wave of the output voltage taking into account ohmic losses
- Авторы: Palchikov E.I.1,2, Ryabchun A.M.1,2
-
Учреждения:
- Lavrentyev Institute of Hydrodynamics, Siberian Branch
- Novosibirsk State University
- Выпуск: Том 61, № 6 (2016)
- Страницы: 919-923
- Раздел: Electrophysics, Electron and Ion Beams, Physics of Accelerators
- URL: https://ogarev-online.ru/1063-7842/article/view/197380
- DOI: https://doi.org/10.1134/S1063784216060165
- ID: 197380
Цитировать
Аннотация
The speed and efficiency of the Tesla transformer at the first half-wave of the output voltage are studied as a function of the Q factors of the circuits and their coupling factor. Calculated results and experimental data are considered. It is shown that for given Q factors, there is an optimal value of the coupling factor providing the highest efficiency, which can be calculated and for which designers should work.
Об авторах
E. Palchikov
Lavrentyev Institute of Hydrodynamics, Siberian Branch; Novosibirsk State University
Автор, ответственный за переписку.
Email: palchikov@hydro.nsc.ru
Россия, pr. Akademika Lavrent’eva 15, Novosibirsk, 630090; ul. Pirogova 2, Novosibirsk, 630090
A. Ryabchun
Lavrentyev Institute of Hydrodynamics, Siberian Branch; Novosibirsk State University
Email: palchikov@hydro.nsc.ru
Россия, pr. Akademika Lavrent’eva 15, Novosibirsk, 630090; ul. Pirogova 2, Novosibirsk, 630090
Дополнительные файлы