Contact resistance in spark plasma sintered segmented legs

Полный текст

Открытый доступ Открытый доступ
Доступ закрыт Доступ предоставлен
Доступ закрыт Только для подписчиков

Аннотация

A method for measuring the contact resistances of segmented thermoelectric legs is developed. The sensitivity of the method is 2 × 10–6 Ω cm2. The contact resistances of junctions upon switching between different segments of thermoelectric materials are measured. Both junctions and materials of the segments are produced by various methods. The determined contact resistances are in the range of 0.8–3.5 Ω cm2. Estimations show that the efficiency loss for a 4-segment leg ~1 cm high at such contact resistances is no more than 5% in the worst case.

Об авторах

I. Drabkin

Joint Stock Company “Giredmet”

Автор, ответственный за переписку.
Email: igordrabk@gmail.com
Россия, Bolshoi Tolmachevskii per. 5, Moscow, 119017

V. Osvensky

Joint Stock Company “Giredmet”

Email: igordrabk@gmail.com
Россия, Bolshoi Tolmachevskii per. 5, Moscow, 119017

A. Sorokin

Joint Stock Company “Giredmet”

Email: igordrabk@gmail.com
Россия, Bolshoi Tolmachevskii per. 5, Moscow, 119017

V. Panchenko

Joint Stock Company “Giredmet”

Email: igordrabk@gmail.com
Россия, Bolshoi Tolmachevskii per. 5, Moscow, 119017

O. Narozhnaia

Joint Stock Company “Giredmet”

Email: igordrabk@gmail.com
Россия, Bolshoi Tolmachevskii per. 5, Moscow, 119017

Дополнительные файлы

Доп. файлы
Действие
1. JATS XML

© Pleiades Publishing, Ltd., 2017

Согласие на обработку персональных данных

 

Используя сайт https://journals.rcsi.science, я (далее – «Пользователь» или «Субъект персональных данных») даю согласие на обработку персональных данных на этом сайте (текст Согласия) и на обработку персональных данных с помощью сервиса «Яндекс.Метрика» (текст Согласия).