The development of Campbell integration system applied in high particle flux measurement
- Авторлар: Wang W.1,2, Cao J.1,2, Zhou X.1,2, Yin Z.1,2
-
Мекемелер:
- State Key Laboratory of Particle Detection and Electronics
- Department of Modern Physics
- Шығарылым: Том 60, № 6 (2017)
- Беттер: 789-794
- Бөлім: Application of Computers in Experiments
- URL: https://ogarev-online.ru/0020-4412/article/view/159961
- DOI: https://doi.org/10.1134/S0020441217060185
- ID: 159961
Дәйексөз келтіру
Аннотация
Campbell Mode is a method widely used in nuclear signal processing. In this article, we introduce the design of the new system based on the Campbell integration measurement applied in NFM (neutron flux measurement) systems for ITER plasma diagnose. In this article, we introduce a digital particle flux measurement system based on Campbell integration theory. A subsequent series of experiment are conducted to test the digital Campbell system performance, which proves that the Campbell integration system is competent for the plasma diagnose in ITER.
Авторлар туралы
Wen-Di Wang
State Key Laboratory of Particle Detection and Electronics; Department of Modern Physics
Хат алмасуға жауапты Автор.
Email: wwdbs@mail.ustc.edu.cn
ҚХР, Hefei, 230026; Hefei, 230026
Jing Cao
State Key Laboratory of Particle Detection and Electronics; Department of Modern Physics
Email: wwdbs@mail.ustc.edu.cn
ҚХР, Hefei, 230026; Hefei, 230026
Xiang Zhou
State Key Laboratory of Particle Detection and Electronics; Department of Modern Physics
Email: wwdbs@mail.ustc.edu.cn
ҚХР, Hefei, 230026; Hefei, 230026
Ze-Jie Yin
State Key Laboratory of Particle Detection and Electronics; Department of Modern Physics
Email: wwdbs@mail.ustc.edu.cn
ҚХР, Hefei, 230026; Hefei, 230026
Қосымша файлдар