The development of Campbell integration system applied in high particle flux measurement


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Campbell Mode is a method widely used in nuclear signal processing. In this article, we introduce the design of the new system based on the Campbell integration measurement applied in NFM (neutron flux measurement) systems for ITER plasma diagnose. In this article, we introduce a digital particle flux measurement system based on Campbell integration theory. A subsequent series of experiment are conducted to test the digital Campbell system performance, which proves that the Campbell integration system is competent for the plasma diagnose in ITER.

About the authors

Wen-Di Wang

State Key Laboratory of Particle Detection and Electronics; Department of Modern Physics

Author for correspondence.
Email: wwdbs@mail.ustc.edu.cn
China, Hefei, 230026; Hefei, 230026

Jing Cao

State Key Laboratory of Particle Detection and Electronics; Department of Modern Physics

Email: wwdbs@mail.ustc.edu.cn
China, Hefei, 230026; Hefei, 230026

Xiang Zhou

State Key Laboratory of Particle Detection and Electronics; Department of Modern Physics

Email: wwdbs@mail.ustc.edu.cn
China, Hefei, 230026; Hefei, 230026

Ze-Jie Yin

State Key Laboratory of Particle Detection and Electronics; Department of Modern Physics

Email: wwdbs@mail.ustc.edu.cn
China, Hefei, 230026; Hefei, 230026

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2017 Pleiades Publishing, Inc.