Test signals choice for system characteristics identification: Taking into account the output deviation range constraint


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

This paper considers active identification methods for the temporal characteristics of an object in a closed-loop control system. A comparative analysis of binary signals, namely, pseudorandom and regular sequences of rectangular pulses, is performed under a constraint imposed on the output deviation range of the controlled parameter. Using calculations, it is shown that the best signal choice depends on several factors and, first of all, on the noise level; under a sufficiently small noise level, the regular binary sequence of rectangular pulses seems preferable.

Авторлар туралы

G. Pikina

National Research University “Moscow Power Engineering Institute,”

Хат алмасуға жауапты Автор.
Email: pikinaga@mpei.ru
Ресей, Moscow

F. Pashchenko

Trapeznikov Institute of Control Sciences

Email: pikinaga@mpei.ru
Ресей, Moscow

Yu. Burtseva

Trapeznikov Institute of Control Sciences

Email: pikinaga@mpei.ru
Ресей, Moscow

Қосымша файлдар

Қосымша файлдар
Әрекет
1. JATS XML

© Pleiades Publishing, Ltd., 2016