Visual acuity at intermediate distances after implantation of different models of intraocular lenses

Cover Page

Cite item

Full Text

Abstract

Aim. To study the rehabilitative effect of treatment of cataracts by implanting trifocal refractive-diffractive soft intraocular lens MIOL-Record 3. Methods. 192 patients (216 eyes) who were operated on for cataract participated in the study. The first (main) group included 63 patients (72 eyes) in whom cataract extraction and implantation of the domestic trifocal refractive-diffractive monolithic (soft) intraocular lens MIOL-Record 3 was performed. The second group included 64 patients (70 eyes) in whom cataract extraction and implantation of the domestic bifocal refractive-diffractive lens MIOL-Accord was performed. The third group consisted of 65 patients (74 eyes) in whom cataract extraction and implantation of the domestic monofocal lens MIOL-2 was performed. Preoperative examination was performed the day before surgery, postoperative - after 7 days, 1, 3, 6 and 12 months. Results. The mean value of visual acuity at a distance of 50 cm without correction in the group of patients with MIOL-Record 3 1 month after surgery was 0.42±0.01 and was significantly higher than such in patients with MIOL-Accord and MIOL-2 - 0.14±0.01 and 0.1±0.001, respectively. A questionnaire survey revealed that in the group with MIOL-Record 3 additional correction with glasses is never used at the intermediate distance in 98.62% of the cases, in groups with MIOL-Accord - in 54.28%, and with MIOL-2 - in 25.68% of cases. Patients with MIOL-Record 3 were completely satisfied with the results of surgery in 70.84% of the cases, and in groups with MIOL-Accord and MIOL-2 - in 54.28, and 27.03% of cases, respectively. Conclusion. The conducted studies have established the best rehabilitative effect of the treatment of cataract during implantation of a trifocal refractive-diffractive intraocular lens MIOL-Record 3.

About the authors

A D Chuprov

Kirov Clinical Ophthalmology Hospital, Kirov, Russia; Kirov State Medical Academy, Kirov, Russia

K S Ivonin

Kirov Clinical Ophthalmology Hospital, Kirov, Russia

Email: doctor_ivonin@mail.ru

A A Zamyrov

Kirov Clinical Ophthalmology Hospital, Kirov, Russia

Yu V Kudryavtseva

Kirov Clinical Ophthalmology Hospital, Kirov, Russia; Kirov State Medical Academy, Kirov, Russia

References

  1. Аветисов С.Э., Егорова Е.А., Мошетова Л.К. и др. Офтальмология: национальное руководство. - М.: ГЭОТАР-Медиа, 2008. - 944 с.
  2. Коронкевич В.П., Ленкова Г.Н., Корольков В.П. Бифокальная интраокулярная линза вместо хрусталика // ФОТОНИКА. - 2008. - №1. - С. 10-13.
  3. Тахтаев Ю.В., Балашевич Л.И. Первый опыт клинического применения мультифокальных интраокулярных линз AcrySof Restor // Офтальмохирургия. - 2004. - №3. - С. 30-34.
  4. Треушников В.М., Чередник В.И. Первая трифокальная интраокулярная линза // Визит к офтальм. - 2007. - №9. - С. 2-17.
  5. Fraco P.H. Postoperative deposits on the AcrySof intraocular lens // Austral. and N. Zealand J. of Ophthalm. - 1999. - Vol. 27, N 5. - P. 301.
  6. Gatinel D., Pagnoulle C., Houbrechts Y. Design and qualification of a diffractive trifocal optical profile for intraocular lenses // J. Cataract. Refract. Surg. - 2011. - Vol. 37, N 11. - P. 2060-2067.
  7. Hoffmann M.B., Spors F., Langenbucher A. et al. Minor effect of blue-light filtering on multifocal electroretinograms // J. Cataract. Refract. Surg. - 2010. - Vol. 36, N 10. - P. 1692-1699.
  8. Lubiński W., Gronkowska-Serafin J., Podboraczyńska-Jodko K. et al. Cataract surgery with bilateral multifocal ReZoom intraocular lens implant ation--comparison of 3 and 12 month follow-up // Klinika Oczna. - 2009. - Vol. 111. - P. 327-331.
  9. Madrid-Costa D., Cerviño A., Ferrer-Blasco T. et al. Visual and optical performance with hybrid multifocal intraocular lenses // Clin. Exp. Optom. - 2010. - Vol. 93, N 6. - P. 426-440.

Supplementary files

Supplementary Files
Action
1. JATS XML

© 2012 Chuprov A.D., Ivonin K.S., Zamyrov A.A., Kudryavtseva Y.V.

Creative Commons License

This work is licensed
under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.





Согласие на обработку персональных данных

 

Используя сайт https://journals.rcsi.science, я (далее – «Пользователь» или «Субъект персональных данных») даю согласие на обработку персональных данных на этом сайте (текст Согласия) и на обработку персональных данных с помощью сервиса «Яндекс.Метрика» (текст Согласия).