Analyzing the reasons for patients’ dissatisfaction with the results of multifocal intraocular lens implantation
- Authors: Ivonin KS1,2
-
Affiliations:
- Kirov Clinical Hospital of Ophthalmology, Kirov, Russia
- Kirov State Medical Academy, Kirov, Russia
- Issue: Vol 95, No 4 (2014)
- Pages: 515-519
- Section: Theoretical and clinical medicine
- URL: https://ogarev-online.ru/kazanmedj/article/view/1833
- DOI: https://doi.org/10.17816/KMJ1833
- ID: 1833
Cite item
Full Text
Abstract
Full Text
##article.viewOnOriginalSite##About the authors
K S Ivonin
Kirov Clinical Hospital of Ophthalmology, Kirov, Russia; Kirov State Medical Academy, Kirov, Russia
Email: doctor_ivonin@mail.ru
References
- Малюгин Б.Э., Тахтаев Ю.В., Морозова Т.А., Поздееева Н.А. Результаты мультицентровых исследований имплантации мультифокальной градиентной ИОЛ третьего поколения (Градиол-3) // Офтальмохирургия. - 2002. - №2. - С. 36-38.
- Тахтаев Ю.В., Балашевич Л.И. Первый опыт клинического применения мультифокальных интраокулярных линз AcrySof Restor // Офтальмохирургия. - 2004. - №3. - С. 30-34.
- Чередник В.И. Моделирование оптической линзы // Известия РАЕН, сер. Математика. Математическое моделирование. Информатика и управление. - 2004. - Т. 8, №1-2. - C. 68-86.
- Agresta B., Knorz M.C., Kohnen T. et al. Distance and near visual acuity improvement after implantation of multifocal intraocular lenses in cataract patients with presbyopia: a systematic review // J. Refract Surg. - 2012. - Vol. 28, N 6. - Р. 426-435.
- Chen W.R., Ye H.H., Qian Y.Y. et al. Comparison of higher-order aberrations and contrast sensitivity between Tecnis Z9001 and CeeOn 911A intraocular lenses: a prospective randomized study // Chinese medical journal. - 2006. - Vol. 119, N 21. - Р. 1779-1784.
- Ferrer-Blasco T., Madrid-Costa D., García-Lázaro S. et al. Stereopsis in bilaterally multifocal pseudophakic patients // Graefes Arch. Clin. Exp. Ophthalmol. - 2011. - Vol. 249, N 2. - Р. 245-251.
- Guttman C. Previous RK may be contraindication to multifocal IOL // Ophthalm. Times. - 1999. - Vol. 24, N 19. - P. 46.
- Hütz W.W., Jäckel R., Hoffman P.C. Comparison of visual performance of silicone and acrylic multifocal IOLs utilizing the same diffractive design // Acta Ophthalm. - 2010. - Vol. 17. - Р. 857-861.
- Lane S.S., Javitt J.C., Nethery D.A. et al. Improvements in patient-reported outcomes and visual acuity after bilateral implantation of multifocal intraocular lenses with +3.0 diopter addition: multicenter clinical trial // J. Cataract Refract. Surg. - 2010. - Vol. 36, N 11. - Р. 1887-1896.
- Mesci C., Erbil H.H., Olgun A. et al. Differences in contrast sensitivity between monofocal, multifocal and accommodating intraocular lenses: long-term results // Clin. Experiment. Ophthalmol. - 2010. - Vol. 38, N 8. - P. 768-777.
- Wang W.Y., Wang J., Zhang J. et al. Clinical observation on visual quality in patients implanted with monofocal and multifocal aspheric intraocular lenses // Zhonghua Yan Ke Za Zhi - 2010. - Vol. 46, N 8. - P. 686-690.
Supplementary files
