Bond strength of restoration materials used for dental ceramics repair

Cover Page

Cite item

Full Text

Abstract

Aim. To assess the bond strength of composite material to ceramic surface of metal-ceramic-fixed dental prosthesis depending on the type of restoration systems used for chipped porcelain restorations. Methods. Bond strength of restoration material to porcelain coating surface were studied according to ISO 10477 issued at 01.10.2004. The surface of the ceramic-metal plates was polished by different methods depending on the restoration system used. Restorative material was applied using a template. Prepared samples were placed in a testing machine and loaded at a constant crosshead speed of 1±0.3 mm/min before separation, the load F at break was registered by an automatic recorder. Results. Similar bond strength results were revealed for restoration systems not requiring acid pickling of porcelain surface («Cimara», «Ceramic Repair») and restoration system including 9.5% hydrofluoric acid «Porcelain etch & silane»: 17.993, 17.774 and 17.896 MPa respectively. Bond strength was much higher (25.278 MPa) if restoration system with 4% hydrofluoric acid was used. «Vertise™ Flow» restorative single-component material also provided significant bond strength - 24.315 MPa. Conclusion. The study showed the possibility of using a single-component restorative material to repair chipped porcelain tile coating metal-ceramic-fixed dental prostheses. For longer life of chipped porcelain tile coating restoration of dental prostheses, the use of restoration systems including 4% hydrofluoric acid is recommended.

About the authors

A A Mikheeva

Moscow State University of Medicine and Dentistry named after A.E. Evdokimov, Moscow, Russia

Email: burmistrova85@mail.ru

G V Bol’shakov

Moscow State University of Medicine and Dentistry named after A.E. Evdokimov, Moscow, Russia

References

  1. Николаев Ю.М. Восстановление сколов облицовочного покрытия металлокерамических протезов с использованием органически модифицированной керамики «Definite» // Панорама ортопед. стоматол. - 2006. - №4. - С. 26-27.
  2. Николаев Ю.М. Внутриротовая починка цельнокерамических конструкций и сколов металлокерамических протезов // Клин. стоматол. - 2008. - №2. - С. 56-58.
  3. International standard ISO 10477 / Dentistry Polymer - based crown and bridge materials, 2004.10.01.
  4. Sailer I., Feher A. Prospective clinical study of zirconia posterior fixed partial dentures: 3 year follow-up // Quentessence. - 2006. - Vol. 37. - Р. 685-693.

Supplementary files

Supplementary Files
Action
1. JATS XML

© 2014 Mikheeva A.A., Bol’shakov G.V.

Creative Commons License

This work is licensed
under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.





Согласие на обработку персональных данных

 

Используя сайт https://journals.rcsi.science, я (далее – «Пользователь» или «Субъект персональных данных») даю согласие на обработку персональных данных на этом сайте (текст Согласия) и на обработку персональных данных с помощью сервиса «Яндекс.Метрика» (текст Согласия).