LONG-TERM RESULTS OF ENHANCED TAPERED STEM VerSys ET USE IN PRIMARY TOTAL HIP ARTHROPLASTY


Cite item

Full Text

Abstract

The authors reported the outcome at a minimum of five years of 130 consecutive arthroplasties of VerSys ET (Zimmer) in 111 patients. The procedures were performed between 2001 and 2004. In 129 cases (99.2%) Trilogy cup (Zimmer) was used in one case - Muller's acetabular cage (Mathys). The mean age of patients was 49.5 (SD 11.5) (23 to 73), male 76 (58.5%), female - 54 (41.5%), overweight patients 109 (83.8%). Majority of patients had activity in Charnley class A. The most frequent was femur Dorr type A (27,0%) and Dorr type В (66,1%). The mean follow-up was 76 months (60 to 96). The outcomes assessed in 103 patients (120 hips) (92.3%). Outcomes of ten cases were not determined. The mean Harris Hip score improves from 35.1 (SD 8.3) preoperatively to 94.3 (SD 8.5) post-operatively. Kaplan-Meier analysis with revision of the stem as the end-point demonstrated 97,7% survival in term 60 to 96 months, for aseptic loosening - 99,2%. Subsidence of the implants in 61 (50.8%) patients was fixed at a mean follow-up 18.3 (SD3.7) months after surgery and did not progress further. After surgery stem position was neutral 91(75.8%) patients, varus - 14 (12.1%) and valgus - 14 (12.1%). Complications were observed in 8 (6.7%) cases: among them - periprosthetic fractures 6 (5.0%), stem aseptic loosening - 1 (0.8%), recurrent dislocation - 1 (0.8%). Four patients undergone revision surgery We consider the high efficiency of VerSys ET stem use for primary total hip arthroplasty.

About the authors

R. M. Tikhilov

ГУ Российский научно-исследовательский институт травматологии и ортопедии им. P.P. Вредена Росмедтехнологий

Email: fake@neicon.ru
д.м.н., профессор, директор Russian Federation

V. M. Shapovalov

Военно медицинская академия им. СМ. Кирова

Email: fake@neicon.ru
д.м.н., профессор, зав. кафедрой военной травматологии и ортопедии Russian Federation

I. I. Artyukh

ГУ Российский научно-исследовательский институт травматологии и ортопедии им. P.P. Вредена Росмедтехнологий

Author for correspondence.
Email: info@rniito.org
к.м.н., ученый секретарь Russian Federation

V. A. Shubnyakov

Военно медицинская академия им. СМ. Кирова

Email: artukhva@mail.ru
к.м.н., преподаватель кафедры военной травматологии и ортопедии Russian Federation

References

  1. Тихилов P.M. Конструктивные особенности различных компонентов эндопротеза тазобедренного сустава/P.M. Тихилов//Руководство по эндопротезированию тазобедренного сустава/под ред. P.M. Тихилова, В.М. Шаповалова. -СПб., 2008. -Гл. 4. -С. 54-117.
  2. Barnett E. The radiological diagnosis of osteoporosis: a new approach/E. Barnett, B.E. Nordin//Clin. Radiol. -1960. -Vol. 11. -P. 166-174.
  3. Brooker A.F. Ectopic ossification following total hip replacement. Incidence and a method of classification/A.F. Brooker, J.W. Bowerman, R.A. Robinson, L.H. Riley//J. Bone Joint Surg. -1973. -Vol. 55-A, N 8. -P. 1629-1632.
  4. Callaghan J. The uncemented porous-coated anatomic total hip prosthesis. Two-year results of prospective consecutive series/J.J. Callaghan, S.H. Dysart, C.G. Savory//J. Bone Joint Surg. -1988. -Vol. 70-A, N 2. -P. 337-346.
  5. Delaunay C. Primary total hip arthroplasty with the Karl Zweymuller first-generation cementless prosthesis. A 5-to 9-year retrospective study/C.P. Delaunay, A.I. Kapandjl//J. Arthroplasty. -1996. -Vol. 11. -P. 643-652.
  6. Delaunay C. Survival analysis of cementless grit-blasted titanium total hip arthroplasties/C. Delaunay, A. Kapandjl//J. Bone Joint Surg. -2001. -Vol. 69-B, N 3. -P. 408-413.
  7. Dorr L. Structural and cellular assessment of bone quality of proximal femur/L.D. Dorr [et al.]//Bone. -Vol.14, N3. -P. 231-242.
  8. Duncan C.P. Fractures of the femur after hip replacement/C.P. Duncan, BA. Masri//Instr. Course Lect. -1995. _ Vol.44. -P. 293-304.
  9. Engh C. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding and clinical results/C.A. Engh, J.D. Bobyn, A.H. Glassman//J. Bone Joint Surg. -1987. -Vol. 69-B, N 1. -P. 45-55.
  10. Engh C. The case for porous-coated hip implants. The femoral side/CA. Engh, A.H. Glassman, K.E. Suthers//Clin. Orthop. -1990. -N 261. -P. 63-81.
  11. Engh C. Roentgenographic assessment of the biological fixation of porous-surfaced femoral components/C.A. Engh, P. Massin, K.E. Suthers//Clin. Orthop. -1990. -N257. -P. 107-112.
  12. Fitzgerald R.H. The uncemented total hip arthroplasty: intraoperative femoral fractures/R.H. Fitzgerald, G.W. Brindley, B.F. Kavanagh//Clin. Orthop. -1988. -N 235. -P. 61-66. 13.
  13. Garcia-Cimbrelo E. Total hip arthroplasty wth use of the cementless Zweymuller Alloclassic System/E. Garcia-Cimbrelo, A. Cruz-Pardos, R. Madero, M. Ortega-Andreu.//J. Bone Joint Surg. -2003. -Vol. 85-A, N 2. -P. 296-303.
  14. Goetz D. The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements/D.D. Goetz, E.J. Smith, W.H. Harris//J. Bone Joint Surg. -1994. -Vol.76-A, N 8. -P. 1121-1129.
  15. Green J. The effect of bone compaction on early fixation of porouscoated implants./J.R. Green [et al.]//J. Arthroplasty. -1999. -Vol. 14. -P. 91-95.
  16. Gruen T. «Modes of failure» of cemented stem-type femoral components/ТА. Gruen, G.M. MvNaice, H.C.Amstutz//Clin. Orthop. -1979. -N 141. -P. 17-27.
  17. Hardinge K. The direct lateral approach to the hip/K. Hardinge//J. Bone Joint Surg. -1982. -Vol. 64-B, N 1. -P. 17-19.
  18. Harris W.H. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation/W.H. Harris//J. Bone Joint Surg. -1969. -Vol. 51-A, N 2. -P. 737-755.
  19. Harwin S.F. Recognizing anterior metaphyseal femoral bone loss during uncemented total hip arthroplasty: the skylight sign/S.F. Harwin//Orthopedics. -2007. -Vol. 30, N3. -P. 218-221.
  20. Huo M.H. Total hip arthroplasty using the Zweymuller stem implanted without cement: A prospective study of consecutive patients with minimum 3-year follow-up period/M.H. Huo, R.P. Martin, L.E. Zatorski, K.J. Keggi//J. Arthroplasty. -1995. -Vol. 10, N 12. -P. 793-799.
  21. Johansson J.E. Fracture of the ipsilateral femur in patients with total hip replacement./J.E. Johansson, R. McBroom, T.W. Barrington, G.A. Hunter//J. Bone Joint Surg. -1981. -Vol. 63-A. -P. 1435-1442.
  22. Kelley S.S. Periprosthetic femoral fractures/S.S. Kelley//J. Am. Acad. Orthop. Surg. -1994. -Vol. 2 -P. 164-172.
  23. Khalily C. Results of a tapered cementless iemoral stem implanted in varus/C. Khalily, K. Lester//J. Arthroplasty. -2002. -Vol.17, N 4. -P. 463-466.
  24. Kobayashi S. Predisposing factors in fixation failure of femoral prostheses following primary Charnley low friction arthroplasty: A 10-to 20-year follow study/S. Kobayashi, S.N. Eftekhar, K.Tereyama//Clin. Orthp. -1994. -N306. -P. 73-83.
  25. Korovessls P. Bone mineral density changes around stable uncemented Zweymueller total hip arthroplasty/P. Korovessls [et al.]//Orthofedics Int. Ed. -1997. -N5. -P. 389-396.
  26. Lewallen D. Femoral fractures associated with hip arthroplasty./D.G. Lewallen, D.K.J. Berry//Reconstructive surgery of the joints/ed. B.F. Morrey. -New York: Chrchill-Livingstone, 1996. -P. 1273-1288.
  27. Lester K. Cross-section radiographic analysis of 10 retrieved titanium alloy press-fit femoral endoprostheses/K.D. Lester//J. Arthroplasty. -1997. -Vol.12, N 8. -P. 930-937.
  28. Min B. The effect of stem alignment of results of total hip arthroplasty with a cementless taperes-wedge femoral component/B. Min [et. al.]//J. Arthroplasty. -2008. -Vol. 23, N 3. -P. 418-423.
  29. Mollan R. Failure of the femoral component in the Howse total hip arthroplasty/R.A. Mollan, P.H. Watters, R. Steele, C.J. McClelland//Clin. Orthop. -1984. -N 190. -P. 142-149.
  30. Scott R.D. Femoral fractures in conjunction with total hip replacement/R.D. Scott, R.H. Turner, S.M. Leitzes, O.E. Aufranc//J. Bone Joint Surg. -1975. -Vol. 57-A. -P. 494-501.
  31. Schwartz J.T. Femoral fracture during non-cemented total hip arthroplasty/J.T. Schwartz, J.G. Mayer, C.A. Engh//J. Bone Joint Surg. -1989. -Vol. 71-A. -P. 1135-1142.
  32. Stuchin SA. Femoral shaft fracture in porous and press-fit total hip arthroplasty/SA. Stuchin//Orthop. Rev. -1990. -Vol. 2. -P. 153-159.
  33. VerSys Enhanced Taper hip prosthesis. Surgical technigue for primary hip arthroplasty. -Zimmer, Inc., 1996. -P. 2.
  34. Vresilovic E. Radiographic assessment of cementless femoral components. Correlation with intraoperative mechanical stability/E.J. Vresilovic, W.J. Hozack, R.H. Rothman//J. Arthroplasty. -2008. -Vol. 23, N 3. -P. 418-423.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2010 Traumatology and Orthopedics of Russia

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».