COMPARISON OF THE EFFECTIVENESS OF SOLID-PHASE EXTRACTION OF DRUGS AND NARCOTIC SUBSTANCES FROM BLOOD FOR MIXEDͳPHASE CARTRIDGES OF SOME BRANDS


Cite item

Full Text

Abstract

Solid-phase extraction (SPE) is one of the modern methods for isolating toxicologically signifi cant substances from biological materials, which include narcotic and medicinal substances, as well as their metabolites. Currently, the market has a large number of proposals for SPE cartridges from various manufacturers. The choice of a suitable cartridge for SPE both in terms of qualitative characteristics and price parameters is a topical issue in the course of chemical-toxicological and forensic chemical analysis.The aim of the research is to evaluate and compare the effectiveness of medicinal and narcotic substances’s extraction from blood for widespread mixed-phase cartridges of some brands, which are intended for solid-phase extraction.Materials and methods. The research comparing the effectiveness of extraction was carried out with the use of mixed-phase cartridges for SPE of the following manufacturers: Bond Elut Certify (Varian), Chromabond Drug (Macherey-Nagel), Strata Screen-C (Phenomenex) EVIDEX SampliQ (Aqilent), HyperSep Vеrify-CX (Thermo), Starlab C8/SCX (Starlab Scientifi c Co., Ltd) with the using of gas chromatograph Agilent 7820 equipped with mass selective detector Agilent 5975 (Agilent, USA).Results and discussion. This article presents the data on the comparison of the effectiveness of the extraction of mixed-phase cartridges for SPE from 5 manufacturers (Bond Elut Certify (Varian), Chromabond Drug (Macherey-Nagel), Strata Screen-C (Phenomenex) EVIDEX SampliQ (Aqilent) и HyperSep Vеrify-CX (Thermo)) for the purposes of screening drugs and narcoticsubstances from blood. The cartridges Starlab C8/SCX of the investigated batch had some signs of poor-quality sorbent in the production.Conclusion. Recommendations for using 5 types of cartridges for the procedure of screening narcotic and medicinal substances in blood during the routine practice of forensic chemical departments and chemical-toxicological laboratories are given. Considering the relative cost of cartridges for SPE, in routine practice it is economically viable to use cartridges from brands Strata Screen-C (Phenomenex) and EVIDEX SampliQ (Aqilent).

About the authors

S. S. Kataev

State healthcare establishment of special type “Perm regional bureau of forensic-medical expertise”

Email: forenschemist@narod.ru

O. N. Dvorskaya

Perm State Pharmaceutical Academy

Email: dvoksnik@gmail.com

References

  1. Chen X.H., Franke J.P., Wijsbeek J., de Zeeuw R.A. Isolation of acidic, neutral, and basic drugs from whole blood using a single mixed-mode solid-phase extraction column // J Anal Toxicol. 1992. Vol. 16. Is. 6. P. 351–355. doi: 10.1093/jat/16.6.351
  2. Chen X.H., Franke J.P., Wijsbeek J., de Zeeuw R.A. Study of lot-to-lot reproducibilities of Bond Elut Certify and Clean Screen DAU mixed-mode solid-phase extraction columns in the extraction of drugs from whole blood // J Chromatogr. 1993. Vol. 617. No. 1. P. 147–151. doi: 10.1016/0378-4347(93)80434-6
  3. Lai C.K., Lee T., Au K.M., Chan A.Y. Uniform solid-phase extraction procedure for toxicological drug screening in serum and urine by HPLC with photodiode-array detection // Clin Chem. 1997. Vol. 43. No. 2. P. 312–325.
  4. Rittner M., Pragst F., Bork W.R., Neumann J. Screening method for seventy psychoactive drugs or drug metabolites in serum based on high-performance liquid chromatography–electrospray ionization mass spectrometry // J Anal Toxicol. 2001. Vol. 25. No. 2. P. 115–124. doi: 10.1093/jat/25.2.115
  5. Takeda A., Tanaka H., Shinohara T., Ohtake I. Systematic analysis of acid, neutral and basic drugs in horse plasma by combination of solid-phase extraction, non-aqueous partitioning and gas chromatography-mass spectrometry // J Chromatogr B Biomed Sci Appl. 2001. Vol. 758. Is. 2. P. 235–248. doi: 10.1016/s0378-4347(01)00189-x
  6. Катаев С.С., Дворская О.Н. Применение твердофазной экстракции в исследовании крови на наркотические и лекарственные вещества // Судебно-медицинская экспертиза. 2012. Т. 55. №4. С. 38–42.
  7. Дворская О.Н., Крохин И.П., Катаев С.С. Опыт применения твердофазной экстракции в скрининге лекарственных и наркотических веществ в крови методом газовой хроматографии с масс-спектрометрическим детектированием // Химико-фармацевтический журнал. 2017. Т. 51. № 3. С. 36–40. doi: 10.1007/s11094-017-1585-4
  8. Катаев С.С., Дворская О.Н., Крохин И.П. Оптимизация процедуры твердофазной экстракции для скрининга лекарственных и наркотических веществ в крови методом газовой хроматографии с масс-спектрометрическим детектированием // Судебно-медицинская экспертиза. 2017. Т. 60. №1. С. 29–35. DOI:10.1017116/sudmed201760129-35
  9. Bogusz M.J., Maier R.D., Schiwy-Bochat K.H, Kohls U. Applicability of various brands of mixed-phase extraction columns for opiate extraction from blood and serum // J Chromatogr B Biomed Sci Appl. 1996. Vol. 683. Is. 2. P. 177–188. doi: 10.1016/0378-4347(96)00120-X
  10. Casale J.F., Piñero E.L. Quantitation of Cocaine by Gas Chromatography-Flame Ionization Detection Utilizing Isopropylcocaine as a Structurally Related Internal Standard // Microgram Journal. 2006. Vol. 4. No. 1–4. P. 47–53.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2017 Kataev S.S., Dvorskaya O.N.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
 

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».