Ultrasound imaging of the brachial plexus in healthy adults and those with neurogenic thoracic outlet syndrome


Cite item

Full Text

Abstract

Ultrasound of the brachial plexus (BP) is a readily available and informative imaging method. Good knowledge of normal BP anatomy and its variations, as well as the ultrasound technique for examining the BP, is the key to success. We present an ultrasound technique for BP assessment in healthy adults and patients with neurogenic thoracic outlet syndrome.

About the authors

Irina Kh. Mukhambetalieva

Medical Center «Clinic of neuromuscular diseases»

Author for correspondence.
Email: i.mukhambetalieva@hotmail.com
Russian Federation, Moscow

Evgeniya S. Druzhinina

Pirogov Russian National Research Medical University

Email: i.mukhambetalieva@hotmail.com
Russian Federation, Moscow

Dmitry S. Druzhinin

Yaroslavl State Medical University

Email: i.mukhambetalieva@hotmail.com
Russian Federation, Yaroslavl

References

  1. Griffith J.F. Ultrasound of the Brachial Plexus. Semin Musculoskelet Radiol 2018; 22: 323–333. doi: 10.1055/s-0038-1645862. PMID: 29791960.
  2. Baute V., Strakowski J.A., Reynolds J.W. et al. Neuromuscular ultrasound of the brachial plexus: A standardized approach. Muscle Nerve 2018; 58: 618–624. doi: 10.1002/mus.26144. PMID: 29672872.
  3. Kerr A.T. The brachial plexus of nerves in man, the variations in its formation and branches. Am J Anat 1918; 23: 285–395. doi: 10.1002/aja.1000230205.
  4. Franco C.D., Williams J.M. Ultrasound-guided interscalene block: reevaluation of the "stoplight" sign and clinical implications. Reg Anesth Pain Med 2016; 41: 452–459. doi: 10.1097/AAP.0000000000000407. PMID: 27203394.
  5. Leonhard V., Caldwell G., Goh M. et al. Ultrasonographic diagnosis of thoracic outlet syndrome secondary to brachial plexus piercing variation. Diagnostics 2017; 7: 40. doi: 10.3390/diagnostics7030040. PMID: 28677632.
  6. Leonhard V., Smith R., Caldwell G., Smith H.F. Anatomical variations in the brachial plexus roots: implications for diagnosis of neurogenic thoracic outlet syndrome. Ann Anat 2016; 206: 21–26. doi: 10.1016/j.aanat.2016.03.011. PMID: 27133185.
  7. Huelke D.F. A study of the transverse cervical and dorsal scapular arteries. Anat Rec 1958; 132: 233–245. doi: 10.1002/ar.1091320302. PMID: 13637401.
  8. Natsis K., Totlis T., Didagelos M. et al. Scalenus minimus muscle: overestimated or not? An anatomical study. Am Surg 2013; 79: 372–374. PMID: 23574846.
  9. Kumar A., Kumar A., Sinha C. et al. Topographic sonoanatomy of infraclavicular brachial plexus: variability and correlation with anthropometry. Anesth Essays Res 2018; 12: 814–818. doi: 10.4103/aer. AER_140_18. PMID: 30662113.
  10. Bianchi S., Martinoli С. Ultrasound of the musculoskeletal system. Medical Radiology 2007. doi: 10.1007/978-3-540-28163-4.
  11. Haun D.W., Cho J.C., Kettner N.W. Normative cross-sectional area of the C5-C8 nerve roots using ultrasonography. Ultrasound Med Biol 2010; 36: 1422–1430. doi: 10.1016/j.ultrasmedbio.2010.05.012. PMID: 20800169.
  12. Naumova E.S., Nikitin S.S., Druzhinin D.S. [Quantitative sonographic characteristics of peripheral nerves in healthy people]. Annaly klinicheskoy i eksperimental’noy nevrologii 2017; 11(1): 55–61. doi: 10.18454/ACEN.2017.1.6162. (In Russ.)
  13. Karmakar M.K., Pakpirom J., Songthamwat B., Areeruk P. High definition ultrasound imaging of the individual elements of the brachial plexus above the clavicle. Reg Anesth Pain Med 2020; 45: 344–350. doi: 10.1136/rapm-2019-101089. PMID: 32102798.
  14. Arányi Z., Csillik A., Böhm J., Schelle T. Ultrasonographic identification of fibromuscular bands associated with neurogenic thoracic outlet syndrome: the "wedge-sickle" sign. Ultrasound Med Biol 2016; 42: 2357–2366. doi: 10.1016/j.ultrasmedbio.2016.06.005. PMID: 27444863.
  15. Drukhinin D.S., Nikitin S.S., Boriskina L.M. et al. [The role of ultrasound examination of the brachial plexus in superior aperture syndrome]. Nervno-myshechnyye bolezni 2020; 10(1): 43–52. doi: 10.17650/2222-8721-2020-10-1-43-52. (In Russ.)
  16. Murtazina A.F., Nikitin S.S., Naumova E.S. [Syndrome of the upper thoracic outlet: clinical and diagnostic features]. Nervno-myshechnyye bolezni 2017; 7(4): 10–19. doi: 10.17650/2222-8721-2017-7-4-10-19. (In Russ.)
  17. Hixson K.M., Horris H.B., McLeod T.C.V., Bacon C.E.W. The diagnostic accuracy of clinical diagnostic tests for thoracic outlet syndrome. J Sport Rehabil 2017; 26: 459–465. doi: 10.1123/jsr.2016-0051. PMID: 27632823.
  18. Orlando M.S., Likes K.C., Mirza S. et al. Preoperative duplex scanning is a helpful diagnostic tool in neurogenic thoracic outlet syndrome. Vasc Endovascular Surg 2016; 50: 29–32. doi: 10.1177/1538574415623650. PMID: 26744377.
  19. Fried S.M., Nazarian L.N. Dynamic neuromusculoskeletal ultrasound documentation of brachial plexus/thoracic outlet compression during elevated arm stress testing. Hand (N Y) 2013; 8: 358–365. doi: 10.1007/s11552-013-9523-8. PMID: 24426950.
  20. Odderson I.R., Chun E.S., Kolokythas O., Zierler R.E. Use of sonography in thoracic outlet syndrome due to a dystonic pectoralis minor. J Ultrasound Med 2009; 28: 1235–1238. doi: 10.7863/jum.2009.28.9.1235. PMID: 19710222.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2020 Mukhambetalieva I.K., Druzhinina E.S., Druzhinin D.S.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».