Pharmacoeconomic Evaluation of Xenon Use in Pediatric Outpatient Dental Practice
- 作者: Khaliullin D.M.1, Lazarev V.V.2,3, Shugailov I.A.4, Gracheva E.S.5
-
隶属关系:
- Dental Forte Elite LLC
- Pirogov Russian National Research Medical University
- Voyno-Yasenetsky Scientific and Practical Center of Specialized Medical Care for Children
- Russian Medical Academy of Continuous Professional Education
- Good Dental LLC
- 期: 卷 29, 编号 3 (2025)
- 页面: 224-230
- 栏目: Original Study Articles
- URL: https://ogarev-online.ru/1728-2802/article/view/313932
- DOI: https://doi.org/10.17816/dent677804
- EDN: https://elibrary.ru/NCGYJX
- ID: 313932
如何引用文章
详细
BACKGROUND: In contemporary health care, including anesthesiology, pharmacoeconomic assessment is integral to evaluating clinical processes. Inhaled anesthetic xenon, known for its unique pharmacologic properties, is gaining popularity in pediatric outpatient dental practice. Evaluating the direct medical costs associated with its use is of particular interest.
AIM: The work aimed to assess the pharmacoeconomic effect of xenon administration in pediatric outpatient dental practice.
METHODS: An open-label, prospective, randomized study included 117 pediatric patients (45 girls, 72 boys). Statistical analysis was performed using Statistica 10.0. Data are presented as median and quartiles (Me [Q1: Q3]); the Mann–Whitney U test was used for intergroup comparisons. A significance level of p ≤ 0.05 was considered statistically significant.
RESULTS: With a mean anesthesia duration of 108 min, the average total xenon consumption per patient was 13 L (7 L/h), corresponding to a direct cost of 36,000 rubles (310 rubles per minute). During the filling the breathing circuit with anesthetic (anesthesia machine–patient), xenon consumption averaged 3 L over 2 min, incurring a cost of 8000 rubles (3000 rubles per minute). During the maintenance phase, xenon consumption averaged 10 L, with associated costs of 28,000 rubles (280 rubles per minute).
CONCLUSION: The highest xenon consumption rate — 1.5 L/min — and the peak cost — 3000 rubles per minute — were observed during the induction phase. The overall mean cost during the entire anesthesia session was nearly 10 times lower than during induction and did not exceed 310 rubles per minute. Future implementation of technologies aimed at reducing xenon loss to the atmosphere during induction may help lower the total cost of its use.
作者简介
Dinar Khaliullin
Dental Forte Elite LLC
编辑信件的主要联系方式.
Email: dr170489@yandex.ru
ORCID iD: 0000-0003-2771-3134
SPIN 代码: 7165-1859
MD, Cand. Sci. (Medicine)
俄罗斯联邦, Naberezhnye ChelnyVladimir Lazarev
Pirogov Russian National Research Medical University; Voyno-Yasenetsky Scientific and Practical Center of Specialized Medical Care for Children
Email: lazarev_vv@inbox.ru
ORCID iD: 0000-0001-8417-3555
SPIN 代码: 4414-0677
MD, Dr. Sci. (Medicine), Professor
俄罗斯联邦, Moscow; MoscowIgor Shugailov
Russian Medical Academy of Continuous Professional Education
Email: 9978753@mail.ru
ORCID iD: 0000-0001-5304-6078
SPIN 代码: 5681-7569
MD, Dr. Sci. (Medicine), Professor
俄罗斯联邦, MoscowElena Gracheva
Good Dental LLC
Email: murzic_elena@icloud.com
ORCID iD: 0000-0002-2758-8065
俄罗斯联邦, Naberezhnye Chelny
参考
- Biro P, Kneschke O, Theusinger OM. Reliability of the volatile agent consumption display in the Draeger Primus™ anesthesia machine. J Clin Monit Comput. 2015;29(5):601–604. doi: 10.1007/s10877-014-9639-6 EDN: YFUYJG
- Neice AE, Zornow MH. Xenon anesthesia for all, or only a select few? Anaesthesia. 2016;71(11):1267–1272. doi: 10.1111/anae.13569
- Goto T, Nakata Y, Morita S. Will xenon be a stranger or a friend?: the cost, benefit, and future of xenon anesthesia. Anesthesiology. 2003;98(1):1–2. doi: 10.1097/00000542-200301000-00002
- Reazaul Karim HM, Sinha M, Kumar M, et al. An observation from an online survey: is fresh gas flow used for sevoflurane and desflurane different from isoflurane-based anesthesia? Med Gas Res. 2019;9(1):13–17. doi: 10.4103/2045-9912.254637
- Mallik T, Aneja S, Tope R, Muralidhar V. A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using “equilibration time” as the change-over point to minimal flow. J Anaesthesiol Clin Pharmacol. 2012;28(4):470–475. doi: 10.4103/0970-9185.101916
- Hanci V, Yurtlu S, Ayoğlu H, et al. Effect of low-flow anesthesia education on knowledge, attitude and behavior of the anesthesia team. Kaohsiung J Med Sci. 2010;26(8):415–421. doi: 10.1016/S1607-551X(10)70067-X
- Kim J, Kang D, Lee H, et al. Change of inspired oxygen concentration in low flow anesthesia. Anesth Pain Med (Seoul). 2020;15(4):434–440. doi: 10.17085/apm.20055 EDN: XVHATG
- Hanne P, Marx T, Musati S, et al. Xenon: uptake and costs. Int Anesthesiol Clin. 2001;39(2):43–61. doi: 10.1097/00004311-200104000-00006
- Dingley J, Findlay GP, Foëx BA, et al. A closed xenon anesthesia delivery system. Anesthesiology. 2001;94(1):173–176. doi: 10.1097/00000542-200101000-00034
- Nakata Y, Goto T, Niimi Y, Morita S. Cost analysis of xenon anesthesia: a comparison with nitrous oxide-isoflurane and nitrous oxide-sevoflurane anesthesia. J Clin Anesth. 1999;11(6):477–481. doi: 10.1016/s0952-8180(99)00087-2
- Luttropp HH, Thomasson R, Dahm S, et al. Clinical experience with minimal flow xenon anesthesia. Acta Anaesthesiol Scand. 1994;38(2):121–125. doi: 10.1111/j.1399-6576.1994.tb03852.x
- Gubaydullin RR, Belousov DYu, Cheberda AE. Сlinical and economic evaluation of inhalation anesthetics use. Messenger of Anesthesiology and Resuscitation. 2017;14(5):8–20. doi: 10.21292/2078-5658-2017-14-5-8-19 EDN: ZSRVZN
- Law LS, Lo EA, Chan CC, Gan TJ. Neurologic and cognitive outcomes associated with the clinical use of xenon: a systematic review and meta-analysis of randomized-controlled trials. Can J Anaesth. 2018;65(9):1041–1056. doi: 10.1007/s12630-018-1163-6 EDN: YBVQDR
- Kulikov A, Sel’Kov D, Kobyakov G, et al. Xenon anesthesia for awake craniotomy: safety and efficacy. Minerva Anestesiologica. 2019;85(2):148–155. doi: 10.23736/S0375-9393 EDN: FFVCUF
- Devroe S, Lemiere J, Van Hese L, et al. The effect of xenon-augmented sevoflurane anesthesia on intraoperative hemodynamics and early postoperative neurocognitive function in children undergoing cardiac catheterization: A randomized controlled pilot trial. Paediatr Anaesth. 2018;28(8):726–738. doi: 10.1111/pan.13444
- Dovgusha VV, Fok MV, Zaritskaya GA. A possible molecular mechanism of the narcotic action of noble gases. Biophysics. 2005;50(5):786–790. EDN: HSCRUF
- Kampman JM, Sperna Weiland NH. Anaesthesia and environment: impact of a green anaesthesia on economics. Curr Opin Anaesthesiol. 2023;36(2):188–195. doi: 10.1097/ACO.0000000000001243 EDN: QKYLGV
补充文件
