Pharmacoeconomic Evaluation of Xenon Use in Pediatric Outpatient Dental Practice

封面

如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

BACKGROUND: In contemporary health care, including anesthesiology, pharmacoeconomic assessment is integral to evaluating clinical processes. Inhaled anesthetic xenon, known for its unique pharmacologic properties, is gaining popularity in pediatric outpatient dental practice. Evaluating the direct medical costs associated with its use is of particular interest.

AIM: The work aimed to assess the pharmacoeconomic effect of xenon administration in pediatric outpatient dental practice.

METHODS: An open-label, prospective, randomized study included 117 pediatric patients (45 girls, 72 boys). Statistical analysis was performed using Statistica 10.0. Data are presented as median and quartiles (Me [Q1: Q3]); the Mann–Whitney U test was used for intergroup comparisons. A significance level of p ≤ 0.05 was considered statistically significant.

RESULTS: With a mean anesthesia duration of 108 min, the average total xenon consumption per patient was 13 L (7 L/h), corresponding to a direct cost of 36,000 rubles (310 rubles per minute). During the filling the breathing circuit with anesthetic (anesthesia machine–patient), xenon consumption averaged 3 L over 2 min, incurring a cost of 8000 rubles (3000 rubles per minute). During the maintenance phase, xenon consumption averaged 10 L, with associated costs of 28,000 rubles (280 rubles per minute).

CONCLUSION: The highest xenon consumption rate — 1.5 L/min — and the peak cost — 3000 rubles per minute — were observed during the induction phase. The overall mean cost during the entire anesthesia session was nearly 10 times lower than during induction and did not exceed 310 rubles per minute. Future implementation of technologies aimed at reducing xenon loss to the atmosphere during induction may help lower the total cost of its use.

作者简介

Dinar Khaliullin

Dental Forte Elite LLC

编辑信件的主要联系方式.
Email: dr170489@yandex.ru
ORCID iD: 0000-0003-2771-3134
SPIN 代码: 7165-1859

MD, Cand. Sci. (Medicine)

俄罗斯联邦, Naberezhnye Chelny

Vladimir Lazarev

Pirogov Russian National Research Medical University; Voyno-Yasenetsky Scientific and Practical Center of Specialized Medical Care for Children

Email: lazarev_vv@inbox.ru
ORCID iD: 0000-0001-8417-3555
SPIN 代码: 4414-0677

MD, Dr. Sci. (Medicine), Professor

俄罗斯联邦, Moscow; Moscow

Igor Shugailov

Russian Medical Academy of Continuous Professional Education

Email: 9978753@mail.ru
ORCID iD: 0000-0001-5304-6078
SPIN 代码: 5681-7569

MD, Dr. Sci. (Medicine), Professor

俄罗斯联邦, Moscow

Elena Gracheva

Good Dental LLC

Email: murzic_elena@icloud.com
ORCID iD: 0000-0002-2758-8065
俄罗斯联邦, Naberezhnye Chelny

参考

  1. Biro P, Kneschke O, Theusinger OM. Reliability of the volatile agent consumption display in the Draeger Primus™ anesthesia machine. J Clin Monit Comput. 2015;29(5):601–604. doi: 10.1007/s10877-014-9639-6 EDN: YFUYJG
  2. Neice AE, Zornow MH. Xenon anesthesia for all, or only a select few? Anaesthesia. 2016;71(11):1267–1272. doi: 10.1111/anae.13569
  3. Goto T, Nakata Y, Morita S. Will xenon be a stranger or a friend?: the cost, benefit, and future of xenon anesthesia. Anesthesiology. 2003;98(1):1–2. doi: 10.1097/00000542-200301000-00002
  4. Reazaul Karim HM, Sinha M, Kumar M, et al. An observation from an online survey: is fresh gas flow used for sevoflurane and desflurane different from isoflurane-based anesthesia? Med Gas Res. 2019;9(1):13–17. doi: 10.4103/2045-9912.254637
  5. Mallik T, Aneja S, Tope R, Muralidhar V. A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using “equilibration time” as the change-over point to minimal flow. J Anaesthesiol Clin Pharmacol. 2012;28(4):470–475. doi: 10.4103/0970-9185.101916
  6. Hanci V, Yurtlu S, Ayoğlu H, et al. Effect of low-flow anesthesia education on knowledge, attitude and behavior of the anesthesia team. Kaohsiung J Med Sci. 2010;26(8):415–421. doi: 10.1016/S1607-551X(10)70067-X
  7. Kim J, Kang D, Lee H, et al. Change of inspired oxygen concentration in low flow anesthesia. Anesth Pain Med (Seoul). 2020;15(4):434–440. doi: 10.17085/apm.20055 EDN: XVHATG
  8. Hanne P, Marx T, Musati S, et al. Xenon: uptake and costs. Int Anesthesiol Clin. 2001;39(2):43–61. doi: 10.1097/00004311-200104000-00006
  9. Dingley J, Findlay GP, Foëx BA, et al. A closed xenon anesthesia delivery system. Anesthesiology. 2001;94(1):173–176. doi: 10.1097/00000542-200101000-00034
  10. Nakata Y, Goto T, Niimi Y, Morita S. Cost analysis of xenon anesthesia: a comparison with nitrous oxide-isoflurane and nitrous oxide-sevoflurane anesthesia. J Clin Anesth. 1999;11(6):477–481. doi: 10.1016/s0952-8180(99)00087-2
  11. Luttropp HH, Thomasson R, Dahm S, et al. Clinical experience with minimal flow xenon anesthesia. Acta Anaesthesiol Scand. 1994;38(2):121–125. doi: 10.1111/j.1399-6576.1994.tb03852.x
  12. Gubaydullin RR, Belousov DYu, Cheberda AE. Сlinical and economic evaluation of inhalation anesthetics use. Messenger of Anesthesiology and Resuscitation. 2017;14(5):8–20. doi: 10.21292/2078-5658-2017-14-5-8-19 EDN: ZSRVZN
  13. Law LS, Lo EA, Chan CC, Gan TJ. Neurologic and cognitive outcomes associated with the clinical use of xenon: a systematic review and meta-analysis of randomized-controlled trials. Can J Anaesth. 2018;65(9):1041–1056. doi: 10.1007/s12630-018-1163-6 EDN: YBVQDR
  14. Kulikov A, Sel’Kov D, Kobyakov G, et al. Xenon anesthesia for awake craniotomy: safety and efficacy. Minerva Anestesiologica. 2019;85(2):148–155. doi: 10.23736/S0375-9393 EDN: FFVCUF
  15. Devroe S, Lemiere J, Van Hese L, et al. The effect of xenon-augmented sevoflurane anesthesia on intraoperative hemodynamics and early postoperative neurocognitive function in children undergoing cardiac catheterization: A randomized controlled pilot trial. Paediatr Anaesth. 2018;28(8):726–738. doi: 10.1111/pan.13444
  16. Dovgusha VV, Fok MV, Zaritskaya GA. A possible molecular mechanism of the narcotic action of noble gases. Biophysics. 2005;50(5):786–790. EDN: HSCRUF
  17. Kampman JM, Sperna Weiland NH. Anaesthesia and environment: impact of a green anaesthesia on economics. Curr Opin Anaesthesiol. 2023;36(2):188–195. doi: 10.1097/ACO.0000000000001243 EDN: QKYLGV

补充文件

附件文件
动作
1. JATS XML

版权所有 © Eco-Vector, 2025


 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».