BACKGROUND: Axiography (condylography) is used to assess the temporomandibular joints (TMJ) function and obtain individual articulator settings. Creating a virtual patient with TMJ dysfunction and determining its individual articulation parameters considerably simplify the procedure and accelerate the diagnosis for further rehabilitation.

AIM: To assess the potential of a virtual articulation system using the Avantis 3D software for determining angular parameters of mandibular movement, considering the individual hinge axis position.

MATERIALS AND METHODS: The clinical phase of the study included 25 volunteers aged 18–30 years, without complaints of TMJ dysfunction, previous orthodontic treatment, and malocclusion.

All volunteers underwent electronic condylography (axiography) using the CADIAX Diagnostic device; the movement of mandible heads during protrusion and mediotrusion was analyzed. The individual values of sagittal condylar inclination (SCI) and Bennett angle on the left and right were obtained. The individual hinge axis was determined, and special radiopaque markers were placed on the skin in the projection of its rotation. Additional markers were placed on the lower edge of the left orbital cavity.

Using these markers, cone beam computed tomography (CBCT) was performed in all volunteers, with a 17.5×20.0 matrix size, to create a 3D project, compare CBCT findings with virtual dental models, and generate a reference plane.

Virtual occlusion measurements were obtained in terminal positions (protrusion and laterotrusion) using the Trios 3 Basic Pod intraoral scanner. The Avantis 3D software was then used to create 3D scenes based on the obtained measurements and CBCT of the skull. The mean length of each path registered for virtual articulator settings in the Avantis 3D software was approximately 3 mm. The interarticular distance used for the analysis was recalculated using the Avantis 3D software to be equal to the standard intercondylar distance of the articulator, which is 110 mm. Individual SCI and Bennett angle values were obtained for all study subjects.

The experimental phase involved phantom models installed in a fully adjustable articulator Reference SL. CBCT was performed with an installed articulator and a maxillary cast, in a zero position, with closed center locks, which was matched to the maxilla present in the CT scan, and a 3D scene was created to measure SCI and Bennett angle values. After detecting the articulator’s hinge axis, electronic measurements of movement were taken, with a predefined SCI of 20–60° (increment 5°) and Bennett angle increments of 6, 12, and 20°. The results were assessed for a path of 3 mm.

RESULTS: The mean difference between the compared determination methods of angular parameters obtained during the experimental phase of the study was 3.20±7.22° for the left SCI; 2.09±9.75° for the right SCI; 5.50±11.26° for the left Bennett angle, and 6.40±6.29° for the right Bennett angle.

The mean difference between the compared determination methods of angular parameters obtained during the clinical phase of the study was 11.80±6.86° for the left SCI; 12.10±6.08° for the right SCI; 13.0±9.89° for the left Bennett angle, and 10.70±11.48° for the right Bennett angle.

CONCLUSION: Both approaches for determining angular parameters can be recommended for use in real-world dental practice. When sophisticated, expensive equipment is not available, a virtual articulation system in the Avantis 3D software can be used as a more simple and affordable technique of measuring angular parameters.

作者简介

Dmitry Kovgan

Peoples' Friendship University of Russia named after Patrice Lumumba

Email: megaspayn@mail.ru
ORCID iD: 0009-0000-2390-0413
SPIN 代码: 3243-8270
俄罗斯联邦, Moscow

Vladislav Erokhin

Samara State Medical University

编辑信件的主要联系方式.
Email: vladalex.171097@mail.ru
ORCID iD: 0000-0003-1096-7568
SPIN 代码: 4724-5883

MD

俄罗斯联邦, 89 Chapaevskaja street, 443099 Samara

Dmitry Trunin

Samara State Medical University

Email: trunin-027933@yandex.ru
ORCID iD: 0000-0002-7221-7976
SPIN 代码: 5951-4659

MD, Dr. Sci. (Medicine), Professor

俄罗斯联邦, 89 Chapaevskaja street, 443099 Samara

Pavel Antonik

Russian University of Medicine

Email: wow-oop@yandex.ru
ORCID iD: 0000-0001-5262-6679
SPIN 代码: 7892-3432
俄罗斯联邦, Moscow

Michail Antonik

Russian University of Medicine

Email: wow-oop@yandex.ru
ORCID iD: 0000-0001-7902-1215
SPIN 代码: 8713-4695

MD, Dr. Sci. (Medicine), Professor

俄罗斯联邦, Moscow

Vitaly Parunov

Peoples' Friendship University of Russia named after Patrice Lumumba

Email: vparunov@mail.ru
ORCID iD: 0000-0003-2885-3657
SPIN 代码: 8797-6513

MD, Dr. Sci. (Medicine), Professor

俄罗斯联邦, Moscow

AAleksandr Ryakhovsky

Central Research Institute of Dentistry and Maxillofacial Surgery

Email: avantis2006@mail.ru
ORCID iD: 0000-0002-0308-126X
SPIN 代码: 5774-4493

MD, Dr. Sci. (Medicine), Professor

俄罗斯联邦, Moscow

参考

  1. Utyuzh AS, Zekij AO, Lushkov RM, et al. Restoring the integrity of the dentoalveolar apparatus in the absence of a fixed interalveolar height using the immediate implant loading technique. The Dental Institute. 2021;(1):65–67. EDN: VEMCZS
  2. Dubova LV, Prisyazhnyh SS, Romankova NV, Malahov DV. Analysis of functional methods for determining the optimal position of the mandible. Parodontologiya. 2020;25(1):22–25. EDN: GFYMVU doi: 10.33925/1683-3759-2020-25-1-22-25
  3. Zhang XX, Liu JZ, Zou W, Wang M. Diagnostic testing using pterygomaxillary notches and retromolar pads on casts to check horizontal jaw relation. Chin J Dent Res. 2021;24(1):61–66. doi: 10.3290/j.cjdr.b1105885
  4. Kattadiyil MT, Alzaid AA, Campbell SD. What materials and reproducible techniques may be used in recording centric relation? Best evidence consensus statement. J Prosthodont. 2021;30(S1):34–42. doi: 10.1111/jopr.13321
  5. Postnikov MA, Nesterov AM, Trunin DA, et al. Possibilities of diagnostics and complex treatment of patients with tmj disfunctions. Clinical Dentistry (Russia). 2020;(1):60–63. EDN: JNDLGX doi: 10.37988/1811-153X_2020_1_60
  6. Kordaß B, Behrendt C, Ruge S. Computerized occlusal analysis — innovative approaches for a practice-oriented procedure. Int J Comput Dent. 2020;23(4):363–375.
  7. Shagibalov RR, Lushkov RM, Utyuzh AS, Zekij AO. Restoring the integrity of the dentoalveolar apparatus in the absence of a fixed interalveolar height using the immediate implant loading technique. Stomatolog. Minsk. 2020;(4):24–29. EDN: XHYFDY doi: 10.32993/dentist.2020.4(39).10
  8. Mamedov AdA, Kharke VV, Morozova NS, et al. Diagnostic methods selection in patients with temporomandibular joint dysfunction. The Dental Institute. 2019;(2):74–77. EDN: HTVSSH
  9. Kolk A, Scheunemann LM, Grill F, et al. Prognostic factors for long-term results after condylar head fractures: A comparative study of non-surgical treatment versus open reduction and osteosynthesis. J Craniomaxillofac Surg. 2020;48(12):1138–1145. doi: 10.1016/j.jcms.2020.10.001
  10. Doroshenko SI, Fedorova AV, Irha SV, et al. Optimization prosthetic treatment of patients with defects in teeth and dentitions, completed by the secondary dento-jaw deformations. Vestnik stomatologii. 2019;32(2):38–42. EDN: VVFALM
  11. Carossa M, Cavagnetto D, Ceruti P, et al. Individual mandibular movement registration and reproduction using an optoeletronic jaw movement analyzer and a dedicated robot: a dental technique. BMC Oral Health. 2020;20(1):271. doi: 10.1186/s12903-020-01257-6
  12. Postnikov MA, Trunin DA, Gabdrafikov RR, et al. Diagnosis of tmj dysfunction and planning of complex dental treatment on a clinical example. The Dental Institute. 2018;(3):78–81. EDN: XZONOH
  13. Ohlendorf D, Fay V, Avaniadi I, et al. Association between constitution, axiography, analysis of dental casts, and postural control in women aged between 41 and 50 years. Clin Oral Investig. 2021;25(5):2595–2607. doi: 10.1007/s00784-020-03571-3
  14. Najdanova IS, Pisarevskij YuL, Shapovalov AG, Pisarevskij IYu. The potential of current technologies in diagnostics of temporomandibular joint dysfunction (literature review). Actual Problems in Dentistry. 2018;14(4):6–13. EDN: VRJMEL doi: 10.18481/2077-7566-2018-14-4-6-13
  15. Park JH, Lee K, Kim JC, et al. Evaluation of mandibular position for splint therapy using a virtual articulator. J Clin Orthod. 2020;54(8):466–472.
  16. Lee H, Burkhardt F, Fehmer V, Sailer I. Accuracy of vertical dimension augmentation using different digital methods compared to a clinical situation — a pilot study. Int J Prosthodont. 2020;33(4):380–385. doi: 10.11607/ijp.6402
  17. Das A, Muddugangadhar BC, Mawani DP, Mukhopadhyay A. Comparative evaluation of sagittal condylar guidance obtained from a clinical method and with cone beam computed tomography in dentate individuals. J Prosthet Dent. 2021;125(5):753–757. doi: 10.1016/j.prosdent.2020.02.033
  18. Parreiras Ferreira R, Isaias Seraidarian P, Santos Silveira G, et al. How a discrepancy between centric relation and maximum intercuspation alters cephalometric and condylar measurements. Compend Contin Educ Dent. 2020;41(4):e1–e6.
  19. Cassi D, De Biase C, Tonni I, et al. Natural position of the head: review of two-dimensional and three-dimensional methods of recording. Br J Oral Maxillofac Surg. 2016;54(3):233–240. doi: 10.1016/j.bjoms.2016.01.025
  20. Lundström F, Lundström A. Natural head position as a basis for cephalometric analysis. Am J Orthod Dentofacial Orthop. 1992;101(3):244–247. doi: 10.1016/0889-5406(92)70093-P
  21. Christensen C. The problem of the bite. Dent Cosmos. 1905;47:1184–1195.

补充文件

附件文件
动作
1. JATS XML
2. Fig. 3. Cone-beam computed tomography of the Reference SL articulator with the upper jaw model installed.

下载 (112KB)
3. Fig. 4. Created 3D scene in the Avantis 3D software for measurements.

下载 (124KB)
4. Fig. 5. Measurement of the condylar path angle set by the articulator scale.

下载 (512KB)
5. Fig. 6. Reference SL articulator with installed CADIAX Diagnostic sensors.

下载 (304KB)
6. Fig. 8. Measurement of angular values in the Avantis 3D software.

下载 (247KB)
7. Fig. 1. Optical records of terminal mandibular positions: (a) protrusion, (b) right laterotrusion, (c) left laterotrusion.

下载 (230KB)
8. Fig. 2. Phantom models mounted in the fully adjustable Reference SL articulator.

下载 (147KB)
9. Fig. 7. Electronic movement recordings with preset angular values.

下载 (92KB)
10. Fig. 9. Recorded angular values: (a) right sagittal condylar inclination, (b) left sagittal condylar inclination, (c) right Bennett angle, (d) left Bennett angle.

下载 (260KB)
11. Fig. 10. Data obtained from Avantis 3D and CADIAX Diagnostic software: (a) right sagittal condylar inclination, (b) left sagittal condylar inclination, (c) left Bennett angle, (d) right Bennett angle.

下载 (269KB)
12. Fig. 11. Mean differences and standard deviations (M±m) between Avantis 3D and CADIAX Diagnostic, ° SCI, sagittal condylar inclination.

下载 (137KB)

版权所有 © Eco-Vector, 2024

许可 URL: https://eco-vector.com/for_authors.php#07
 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».