The adhesive properties of the “Tachocomb” hemostatic plate with prostheses of the brain dura mater

封面

如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The adhesion of the Tahokomb hemostatic plate of Takeda (Japan) to the solid cerebral membrane prostheses from materials of various origins was experimentally investigated to determine which of them the implants under study best provide tachocomb fixation and contribute to the prevention of postoperative liquorrhea and infectious complications resulting from leaks in the subdural space. It was found that the greatest adhesion of tachocomb was revealed to xenogenic prostheses having collagen in their composition, which characterizes them as optimal prostheses for plasticizing defects of the solid cerebral membrane from the point of view of sealing the subdural space. Intermediate values were observed in the study of prostheses of combined origin, and the lowest adhesion of tachocomb was observed with respect to synthetic prostheses. Of some interest are new composite substitutes for the hard brain (NeoDura, Medprin), created as a mix of synthetic and organic materials. The surface texture of these solid cerebral membrane analogues approaches collagen implants in characteristics, and is similar to the structure of the native solid cerebral membrane. Based on the data obtained, we can talk about the priority use of solid braincase prostheses based on animal collagen - not only due to the high adhesion parameters of tachocomb to them, but also due to other qualities: resorbability, facilitating the deposition of recipient fibroblast materials on the surface.

作者简介

Vyacheslav Vinogradov

Military Medical Academy named after S.M. Kirov of the Ministry of Defense of the Russian Federation

编辑信件的主要联系方式.
Email: ulytreack@gmail.com
ORCID iD: 0000-0001-5930-3805
SPIN 代码: 9629-1818

cadet

俄罗斯联邦, Saint Petersburg

Dmitriy Alekseev

Military Medical Academy named after S.M. Kirov of the Ministry of Defense of the Russian Federation

Email: dealekseev@mail.ru
ORCID iD: 0000-0002-8685-3965
SPIN 代码: 9823-8976

candidate of medical sciences

俄罗斯联邦, Saint Petersburg

Dmitriy Svistov

Military Medical Academy named after S.M. Kirov of the Ministry of Defense of the Russian Federation

Email: kolba81@yandex.ru
ORCID iD: 0000-0002-3922-9887
SPIN 代码: 3184-5590

candidate of medical sciences, associate professor

俄罗斯联邦, Saint Petersburg

参考

  1. Alekseev DE, Alekseev ED, Svistov DV. Comparative analysis of dural reconstruction methods in open brain surgery for prevention of postoperative cerebrospinal fluid leakage. Kazan medical journal. 2014; 95(1):45–49. (In Russ.) doi: 10.17816/kmj1454
  2. Riley ET. Comment on arachnoid and dura mater lesions. Regional Anesthesia Pain Medicine. 2018;43(3):323–332. doi: 10.1097/aap.0000000000000753
  3. Odar J, Sepehrnia A, Schachtle R. Methods for repairing and regenerating human dura mater. Unaited States Patent US US8834864B2.b. 2014 Sep. 16.
  4. Shimanskiy VN, Poschataev VK, Odamanov DA. A technique of TachoComb application in dura mater reconstruction in surgery for posterior cranial fossa tumors. Voprosy Neirokhirurgii im. NN. Burdenko. 2016;80(5):85–89. (In Russ.) doi: 10.17116/neiro201680585-89
  5. Mustafayev BS, Mustafayeva AS. Posttraumatic liquorrhea: diagnosis and surgical treatment. Neyrokhirurgiya i nevrologiya Kazakhstana. 2017; (3):37–40. (In Russ.)
  6. Shelesko EV, Kravchuk AD, Capitanov DN. A modern approach to the diagnosis of nasal liquorrhea. Voprosy Neirokhirurgii im. NN. Burdenko. 2018;82(3):103–111. (In Russ.) doi: 10.17116/neiro2018823103
  7. Agger P, Langhoff J, Smerup MH. Comparison between TachoComb and TachoSil for surgical hemostasis in arterial bleeding: an animal experimental study. Journal of Trauma and Acute Care Surgery. 2010;68 (4):838–842. doi: 10.1097/ta.0b013e3181b1388c
  8. Alekseev DE, Svistov DV, Nevrotin AI. The ultrastructure of dura mater of brain and its substitutes. Vestnik Rossiyskoy Voenno-Meditsinskoy Akademii. 2016;(4):103–112. (In Russ.)
  9. Reddy M, Schöggl A, Reddy B. Watertightness and effectiveness of a fibrinogen-based collagen fleece (TachoComb®) in neurosurgery. European Surgery. 2003;35:278–281. doi: 10.1007/s10353-003-0027-6
  10. Yoshioka N. Cranial reconstruction following the removal of an infected synthetic dura mater substitute. Plastic and Reconstructive Surgery Global Open. 2014;2(4):e134. doi: 10.1097/gox.0000000000000087
  11. Hao WA. Hui NG, Kang CG. Preliminary exploration of the development of a collagenous artificial dura mater for sustained antibiotic release. Chinese Medical Journal. 2013;126(17):3329–3333.
  12. Târcoveanu E, Lupaşcu C, Moldovanu R. Fibrin-collagen patch (TachoComb) in general surgery. Indications and results. Revista medico-chirurgicala a Societatii de Medici si Naturalisti din Iasi. 2007;111(2):396–401.
  13. Kawasaki S, Origasa H, Tetens V. Comparison of TachoSil and TachoComb in patients undergoing liver resection – a randomized, double-blind, non-inferiority trial. Langenbeck’s Archives of Surgery. 2017;402(4):591–598. doi: 10.1007/s00423-017-1571-z
  14. Komatsu K, Fujii A, Higami T. Haemostatic fleece (TachoComb®) to prevent intrapleural adhesions after thoracotomy: a rat model. The Thoracic and cardiovascular surgeon. 2007;55(6):385–390. doi: 10.1055/s-2007-965174
  15. Lee JY, Ebel H, Friese M. Influence of TachoComb® in comparison to local hemostyptic agents on epidural fibrosis in a rat laminectomy model. Minimally Invasive Neurosurgery. 2003;46(2):106–109. doi: 10.1055/s-2003-39335
  16. Karasu H, Güzel I. Comparison TachoComb with SurgiWrap, Surgicel and Lyodura in epidural fibrosis: an experimental rat model. Ideggyogy Sz. 2016;69(5–6):195–200. doi: 10.18071/isz.69.0195
  17. Cho JM, Ahn JY, Chang JH. Prevention of cerebrospinal fluid rhinorrhea after transsphenoidal surgery by collagen fleece coated with fibrin sealant without autologous tissue graft or postoperative lumbar drainage. Operative Neurosurgery. 2011;68(1):130–137. doi: 10.1227/neu.0b013e318207b4ea
  18. Wiatr M, Składzień J, Moskała M. Massive posttraumatic otorrhoea. The Journal of International Advanced Otology. 2013;9(3):55–59.
  19. Kim YW, Kang MJ, Lee HJ. The efficacy of TachoComb on reducing postoperative complications after tonsillectomy in children. Int J Pediatr Otorhinolaryngol. 2015;79(8):1337–1340. doi: 10.1016/j.ijporl.2015.06.006

补充文件

附件文件
动作
1. JATS XML

版权所有 © Vinogradov V.V., Alekseev D.E., Svistov D.V., 2021

Creative Commons License
此作品已接受知识共享署名-非商业性使用-禁止演绎 4.0国际许可协议的许可。

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».