Preparation of 188Re-Labetalol as a β1-Adrenoceptor for Use in Nuclear Medicine


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Labetalol was labeled with 188Re. The reaction conditions (amounts of stannous chloride and substrate, pH, time) were optimized, and the radiochemical yield as high as 95 ± 0.4% was reached. Biodistribution in mice was studied. 188Re-Labetalol showed excellent initial heart uptake and good retention. The heart/liver ratios were 5.16, 2.70, and 2.15 at 30, 60, and 120 min post injection, respectively.

About the authors

F. A. Marzook

Labeled Compounds Department, Hot Laboratories Center

Author for correspondence.
Email: fawzymarzouk@yahoo.com
Egypt, Cairo

H. E. Ramadan

Radioactive Isotopes and Generator Department, Hot Laboratories Center

Email: fawzymarzouk@yahoo.com
Egypt, Cairo

H. M. Talaat

Labeled Compounds Department, Hot Laboratories Center

Email: fawzymarzouk@yahoo.com
Egypt, Cairo

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2019 Pleiades Publishing, Inc.