Lung cancer risks due to the radon in cigarette tobacco


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

Thirty-one tobacco samples were evaluated for the activity concentrations of radon and radium using solid-state nuclear track detectors (CR-39). The detectors were exposed for a period of 150 days to different types of cigarette tobacco. The highest values of 364 Bq m–3 for radon and 31.4 Bq kg–1 for radium were obtained for MIA2 sample, and the lowest values of 20.2 Bq m–3 for radon and 1.74 Bq kg–1 for radium, for SUM sample. According to the estimate, this range of radon levels corresponds to the lung cancer incidence in the range 22–396 cases per million smoker per year. The annual effective dose in general and for lungs in particular, the surface and mass exhalation rate, the equivalent equilibrium concentration of radon, and absorbed dose to tissues and lungs were calculated. The highest values were obtained for MIA2 sample, and the lowest values, for SUM sample.

Sobre autores

A. Ridha

Department of Physics, College of Science

Autor responsável pela correspondência
Email: dr.ali@uomustansiriyah.edu.iq
Iraque, Baghdad

H. Hasan

Department of Medical Physics, College of Dentistry

Email: dr.ali@uomustansiriyah.edu.iq
Iraque, Baghdad

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Pleiades Publishing, Inc., 2017