2D Synchrotron Radiation Interferometer for Measuring the Transverse Dimensions of an Electron Beam in a Circular Accelerator


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

In the majority of cases, modern systems for measuring the transverse profile of the electron beam in storage rings of synchrotron type work in the x-ray range in order to overcome the resolution limit imposed by diffraction. In conjunction with devices of this type, use is frequently made of a synchrotron radiation interferometer operating in the visible wavelength range. With the help of such an interferometer, consisting of a screen with two slits (1D interferometer), it is possible to measure the transverse dimension down to a few micrometers. 1D interferometers are widely used in circular accelerators throughout the world, including a PETRA III (DESY) storage ring, where such an interferometer is used to determine the vertical dimension of the beam. It is proposed to use a 2D interferometer, consisting of a screen with four circular holes, making it possible to measure the vertical and horizontal dimensions simultaneously.

作者简介

A. Novokshonov

National Research Tomsk Polytechnic University

编辑信件的主要联系方式.
Email: novokshonov@tpu.ru
俄罗斯联邦, Tomsk

A. Potylitsyn

National Research Tomsk Polytechnic University; National Research Nuclear University MEPhI

Email: novokshonov@tpu.ru
俄罗斯联邦, Tomsk; Moscow

G. Kube

Deutsches Elektronen-Synchrotron (DESY); National Research Nuclear University MEPhI

Email: novokshonov@tpu.ru
德国, Hamburg; Moscow

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media, LLC, 2017