Metal Evaporation in the Area of an Anode Spot in Plasma and Direct Current Arc Steel Smelting Furnaces
- Authors: Simonyan L.M.1, Alpatova A.A.1
-
Affiliations:
- National University of Science and Technology MISiS
- Issue: Vol 61, No 9-10 (2018)
- Pages: 853-857
- Section: Article
- URL: https://ogarev-online.ru/0026-0894/article/view/240890
- DOI: https://doi.org/10.1007/s11015-018-0575-4
- ID: 240890
Cite item
Abstract
Results are given for laboratory research making it possible to describe identical processes in industrial direct current arc furnaces. On the basis of studying the dependence of iron specific evaporation rate in the anode spot zone on current density and time, an expression is obtained making it possible to evaluate the evaporation rate in the anode spot zone in these furnaces of any capacity. It is based on an analytical relationship of permissible current density on electrode diameter over a broad range of change.
About the authors
L. M. Simonyan
National University of Science and Technology MISiS
Author for correspondence.
Email: lmsimonyan@yandex.ru
Russian Federation, Moscow
A. A. Alpatova
National University of Science and Technology MISiS
Email: lmsimonyan@yandex.ru
Russian Federation, Moscow
Supplementary files