Installation of the cooling system. In cases where the compressor is ordered complete with an OS system, a control unit, a temperature sensor with its connecting wire and an injector (one injector for four-cylinder compressors, two for six-cylinder compressors) are installed on it at the factory. The nozzle is closed with a screw plug. The pulse non-magnetic injection valve, equipped with power supply connectors, is delivered in a separate package to prevent possible damage during transportation. Mount the valve on the compressor before checking the tightness of the circuit.

References

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Rice. 1. Base plate for the control unit of the CTC system on compressors of models: a from 4Z-5.2 to 451-12.2; b - from 4 7 -3.2 to 61-40.2; 1 base plate; 2-long base plate bolts

Download (274KB)
3. Rice. Fig. 2. Mounting points for the temperature sensor and injection nozzle(s) for compressors: a - four-cylinder models from 47-5.2 to 4N-12.2: 1 - hole for the temperature sensor; 2 - hole for the nozzle; b - four-cylinder models from 4Z-13.2 to 4G-20.2: 1 - hole for the temperature sensor; 2 - hole for the nozzle; c - for six-cylinders with a hole for the nozzle size 1.65 "(pos. 2) and size 1.2" (pos. 3); d - side view (from the side opposite the sight glass) of the compressor shown in fig. 2, in

Download (277KB)
4. Rice. 3. The position of the injection pulse solenoid valve when installed on four-cylinder compressors of models from 4Z-52 to 4N -12.2 (the valve coil is conventionally not shown): 1- injection valve: 2 - clamping collar; 3 - bolt M6x12; 4 - nut Mb; 5 - mounting bracket; 6 - nozzle; 7 — paw for attaching an additional fan; 8 - spring washer; 9 - hairpin; 10 - cylinder head; 11- nut M 10

Download (273KB)
5. Rice. Fig. 4. The position of the impulse solenoid injection valve when installed on four-cylinder compressors of models from 47-13.2 to 4G-20.2 (the valve coil is conventionally not shown): 1 - mounting bracket; 2 - injection valve; 3 - clamping collar; 4 - cylinder head; 5 - cylinder head bolt; 6 - bolt M6x12; 7 - nut Mb; 8 - nozzle

Download (261KB)
6. Rice. Fig. 5. The position of the impulse solenoid injection valve when installed on six-cylinder compressors of models from 67-22.2 to 6F-40.2 (the valve coil is conventionally not shown): 1 - injection valve; 2 - clamping collar; 3 - bolt M6x12; 4 - nut Mb; 5 - mounting bracket (two different models); 6 - cylinder head; 7 - fixing bolt of the head of the block; 8 - nozzle 1.2"; 9 - nozzle 1.65"

Download (510KB)
7. Pic. 6. Scheme of connecting elements of the C1C system to the control unit; 1 - injection valve contact; 2 - alarm contact; 3 - safety circuit contact; 4 - power supply connection terminals; 5 - manual activation of the C1C system; A1/A2 alarm (no voltage at the terminals); M 1 / M2 - compressor contactor control circuit (no voltage at the terminals); L /N - power supply voltage; PE - terminals for grounding connection; PE/ 1)Ch:/2 - terminals for connecting the shielding braid of the temperature sensor cable; R 10 - temperature sensor. K5 injection valve (normally closed); K1 - compressor contactor; F14 - fuse for the C1C system booster unit, rated for a rated current of 4A

Download (283KB)

Copyright (c) 2022 Board E.