Analysis of losses in fan coil units by using the entropy-statistical method

Cover Page

Cite item

Full Text

Abstract

BACKGROUND: Systems with chillers and fan coil units are widely used in air conditioning. Therefore, entropy-statistical analysis of energy losses in a duct-type two-pipe fan coil unit with controlled air flow is relevant.

AIM: This work aimed to review a method for determining losses by using the entropy-statistical method and to calculate losses due to non-ideal heat transfer and hydraulic losses in fan coil units.

MATERIALS AND METHODS: Losses were determined using the entropy-statistical method.

RESULTS: A comparative analysis of the results was performed. Diagrams of the distribution of loss components and recommendations for their reduction are presented.

About the authors

Valentina V. Osipenko

VEZA

Email: region@veza.ru

Engineer

Russian Federation, Moscow Region

Nikolai A. Lavrov

Bauman Moscow State Technical University

Author for correspondence.
Email: 79035596471@yandex.ru
SPIN-code: 9187-7444

Dr. Sci. (Tech.), Professor

Russian Federation, 5, 2-nd Baumanskaya, Moscow, 105005

References

  1. Arharov AM. Osnovy kriologii. Jentropijno-statisticheskij analiz nizkotemperaturnyh sistem. Moscow: Izdatel’stvo MGTU im. N.Je. Baumana, 2014, 507 p. (in Russ.).
  2. Shishov VV, Talyzin MS. Prakticheskoe primenenie jentropijno-statisticheskogo metoda analiza holodil’nyh ciklov. Refrigeration Technology. 2015;104(3):25–30. (in Russ.). doi: 10.17816/RF98878
  3. Arharov AM, Shishov VV, Talyzin MS. Jentropijno-statisticheskij analiz nizkotemperaturnyh holodil’nyh ciklov i vybor na ego osnove optimal’noj sistemy holodosnabzhenija magazina. Refrigeration Technology. 2016;105(3):30–34. (in Russ.). doi: 10.17816/RF99047
  4. Zdobnov MI, Lavrov NA, Shishov VV. Analiz poter’ v teploobmennike teploutilizatore s pomoshh’ju jentropijno-statisticheskogo metoda. Refrigeration Technology. 2019;108(2): 37–40. (in Russ.). doi: 10.17816/RF99501
  5. Zdobnov MI, Lavrov NA, Shishov VV, Karakulov SI. Analiz poter’ v isparitel’no kondensatornom konture central’nogo kondicionera s pomoshh’ju jentropijno-statisticheskogo metoda. Refrigeration Technology. 2019;108(8):28–33. (in Russ.). doi: 10.17816/RF104152
  6. Zdobnov MI, Lavrov NA. Analiz poter’ v ventiljacionnyh ustanovkah s pomoshh’ju jentropijno-statisticheskogo metoda. Refrigeration Technology. 2018;107(8):36–41. (in Russ.). doi: 10.17816/RF99432
  7. Tishhenko IV, Abalakin SA, Merkulov VI, et al. Jentropijno-statisticheskij analiz sistemy kondicionirovanija vozduha passazhirskogo samoleta. Holodil’naja i kriogennaja tehnika, sistemy kondicionirovanija i zhizneobespechenija: materialy Tret’ej mezhdunarodnoj nauchnoj konferencii. 2020, p. 318–326. (in Russ.).
  8. Arharov AM, Arharov IA, Sychjov VV, et al. O rezul’tatah jentropijnogo i jeksergeticheskogo analiza processa smeshenija chastej ideal’nogo gaza raznoj temperatury // Refrigeration Technology. 2014;103(7):35–39. (in Russ.). doi: 10.17816/RF98779
  9. Belova EM. Sistemy kondicionirovanija s chillerami i fjenkojlami. Moscow: Izd-vo Evroklimat, 2003, 400 p. (in Russ.).

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Fig. 1. Duct-type two-pipe fan coil unit VENDO-KS-10/2-N.

Download (81KB)
3. Fig. 2. Energy losses due to non-ideal heat transfer.

Download (81KB)
4. Fig. 3. Energy loss in the fan.

Download (72KB)
5. Fig. 4. Hydraulic losses from the passage of liquid through the heat exchanger.

Download (90KB)

Copyright (c) 2022 Osipenko V.V., Lavrov N.A.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Согласие на обработку персональных данных

 

Используя сайт https://journals.rcsi.science, я (далее – «Пользователь» или «Субъект персональных данных») даю согласие на обработку персональных данных на этом сайте (текст Согласия) и на обработку персональных данных с помощью сервиса «Яндекс.Метрика» (текст Согласия).