Vapor–liquid critical flow through a layer of spherical particles


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Vapor–liquid flow in a cylindrical channel through fillings of spherical particles is studied experimentally. Data on the critical flow of a vapor–water mixture with various vapor contents through densely packed layers of spherical particles from stainless steel with diameters of 2 and 4 mm for a filling column height of 250 and 355 mm are obtained. Experimental data demonstrate the influence of pressure, the vapor content of the mixture at the input, and the geometric parameters of the filling on the critical mass velocity. The linear dependence of the critical mass velocity on the geometric factor \(\sqrt {d/H} \). The possibility of generalizing the experimental results based on the gas dynamic model for the flow of a homogeneous medium is considered.

作者简介

E. Tairov

Melentiev Energy Systems Institute, Siberian Branch

编辑信件的主要联系方式.
Email: tairov@isem.sei.irk.ru
俄罗斯联邦, Irkutsk, 664033

B. Pokusaev

Moscow State University of Mechanical Engineering

Email: tairov@isem.sei.irk.ru
俄罗斯联邦, Moscow, 107884

S. Bykova

Melentiev Energy Systems Institute, Siberian Branch

Email: tairov@isem.sei.irk.ru
俄罗斯联邦, Irkutsk, 664033

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2016