Balancing Flow Rate Distribution Between Separate Devices in Plate-Fin Heat Exchanger Units
- 作者: Matveev S.A.1, Smorodin A.I.2
-
隶属关系:
- Cryogenmash Company
- Bauman Moscow State Technical University
- 期: 卷 51, 编号 11-12 (2016)
- 页面: 783-785
- 栏目: Article
- URL: https://ogarev-online.ru/0009-2355/article/view/234286
- DOI: https://doi.org/10.1007/s10556-016-0122-8
- ID: 234286
如何引用文章
详细
The non-uniformity of flow rate distribution between separate devices of the plate-fin heat exchanger units working as a part of air separation plant, exceeding 2% of the nominal value, significantly reduces integral characteristics of the unit. Shortcomings of the method for regulating uniformity of flow rate distribution in the plate-fin heat exchanger units by means of regulating valves are considered. It is suggested to use a different approach allowing to avoid the use of expensive regulating valves and to specify the conditions to provide the required uniformity of flow rate distribution between separate heat exchangers already at the preliminary design stage.
作者简介
S. Matveev
Cryogenmash Company
编辑信件的主要联系方式.
Email: matveev@cryogenmash.ru
俄罗斯联邦, Balashikha, Moscow Oblast
A. Smorodin
Bauman Moscow State Technical University
Email: matveev@cryogenmash.ru
俄罗斯联邦, Moscow
补充文件