Modeling of 3D Implants via Personalized Contour Correction with Evaluation of Bone Tissue Density on the Hounsfield Scale


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

Increases in the numbers of surgical procedures for primary joint replacement inevitably lead to increases in the requirements for revision replacement of the hip joint. The number of patients with severe destruction of the acetabulum, in whom achievement of the implant stability is difficult or impossible, has increased. Manufacture of custom-made acetabular components is indicated in these cases. This article describes a method of filling defects in pelvic bones with custom-made implants 3D printed from medical titanium LPW-TI64-GD23-TYPE5 as specified by ASTM F136. The implant model is manufactured based on results of measurements of the density of the surrounding bone tissue using the Hounsfield scale.

Sobre autores

M. Sadovoy

Novosibirsk Research Institute of Traumatology and Orthopaedics n.a. Ya. L. Tsivyan

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

V. Pavlov

Novosibirsk Research Institute of Traumatology and Orthopaedics n.a. Ya. L. Tsivyan

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

V. Bazlov

Novosibirsk Research Institute of Traumatology and Orthopaedics n.a. Ya. L. Tsivyan

Autor responsável pela correspondência
Email: sbazlov@yandex.ru
Rússia, Novosibirsk

T. Mamuladze

Novosibirsk Research Institute of Traumatology and Orthopaedics n.a. Ya. L. Tsivyan

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

M. Efimenko

Novosibirsk Research Institute of Traumatology and Orthopaedics n.a. Ya. L. Tsivyan

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

V. Prokhorenko

Novosibirsk Research Institute of Traumatology and Orthopaedics n.a. Ya. L. Tsivyan

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

E. Mamonova

AO Innovative Medical Technology Center (Medical Technopark)

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

I. Kirilova

Novosibirsk Research Institute of Traumatology and Orthopaedics n.a. Ya. L. Tsivyan

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

A. Aronov

AO Innovative Medical Technology Center (Medical Technopark)

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

A. Panchenko

OOO 3D Medical Systems

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

N. Fomichev

Novosibirsk Research Institute of Traumatology and Orthopaedics n.a. Ya. L. Tsivyan

Email: sbazlov@yandex.ru
Rússia, Novosibirsk

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Springer Science+Business Media, LLC, part of Springer Nature, 2018