Surgical techniques of intraocular lens-capsular bag complex stabilization during cataract phacoemulsification in patients with lens subluxation

Cover Page

Cite item

Full Text

Abstract

Aim. To develop and to assess the efficacy of the method of one-step upper fixation of a single-piece intraocular lens to the iris during cataract phacoemulsification in patients with lens subluxation.

Methods. The study included 32 patients (37 eyes) with complicated cataract grade 2–3 combined with grade 1–2 lens subluxation. Both groups underwent cataract phacoemulsification with consequent implantation of a capsular tension ring and a single-piece intraocular lens. Group 1 (21 eyes) underwent intraoperative one-step upper haptic fixation of a single-piece intraocular lens in vertical position. In group 2 (16 eyes) in 13 cases 6±1.5 months later a single piece intraocular lens was repositioned and both haptics were sutured to the iris.

Results. In both groups no intraoperative complications occured. Visual acuity in group 1 on days 1–3 after the surgery was 0.77±0.19 and was stable during the follow-up. Intraocular pressure was 17.2±0.99 mm Hg. In group 2 the obtained good functional results 0.78±0.18 declined due to intraocular lens decentration, the intraocular pressure increased by 6.0±1.25 mm Hg (up to 24.2±0.65 mm Hg) which required an intraocular lens reposition in 81.3% of cases. According to ultrasound biomicroscopy, in both groups intraocular lens in all cases had intracapsular fixation and was in a central position.

Conclusion. The developed method of a one-step single piece intraocular lens fixation by suturing the upper haptic to the iris during cataract phacoemulsification in patients with lens subluxation is an effective and safe procedure that allows complete rehabilitation of patients with phacodonesis during a one-step surgical intervention.

About the authors

S Yu Kopaev

S.N. Fyodorov Eye Microsurgery Federal State Institution

Email: burtseva-alena@yandex.ru
SPIN-code: 4270-0480
Russian Federation, Moscow, Russia

I A Il´inskaya

Pirogov Russian National Research Medical University

Email: burtseva-alena@yandex.ru
SPIN-code: 4029-5441
Russian Federation, Moscow, Russia

A A Burtseva

S.N. Fyodorov Eye Microsurgery Federal State Institution

Author for correspondence.
Email: burtseva-alena@yandex.ru
Russian Federation, Moscow, Russia

References

  1. Osipova T.A., Eroshevskaya E.B., Malov I.V. Comparative results of surgical treatment of patients with the lens subluxation. Vestnik OGU. 2013; (4): 197–200. (In Russ.)
  2. Titiyal J.S., Kaur M., Rathi A., Falera R. Femtose­cond laser-assisted successful management of subluxa­ted cataractous lens with vitreous in anterior chamber. In­dian J. Ophthalmol. 2019; 67 (1): 155–157. doi: 10.4103/ijo.IJO_764_18.
  3. Belonozhenko Ya.V., Sorokin E.L. Option of a choice method of surgical correction of aphakia in the performance of phacoemulsification aged-related cataract with mild degree of the lens subluxation. Prakti­cheskaya meditsina. 2012; (4): 263–266. (In Russ.)
  4. Semakina A.S., Malyugin B.E., Pokrovskiy D.F. et al. Ana­tomic-topographic position of the IOL in irido-capsular and irido-vitreous fixation. Sovremennye tekhnologii v oftalʹmologii. 2016; (4): 213–216. (In Russ.)
  5. Miroshnikov V.V. Aphakia correction method in the absence of capsular support. Sovremennye tekhnologii v oftalʹmologii. 2015; (4): 72–73. (In Russ.)
  6. Toro M.D., Longo A., Avitabile T. et al. Five-year follow-up of secondary iris-claw intraocular lens implantation for the treatment of aphakia: Anterior chamber versus re­tropupillary implantation. PLoS One. 2019; 14 (4): e0214140. doi: 10.1371/journal.pone.0214140. Collection 2019.
  7. Pashtaev N.P. Surgery of the lens subluxated and dislocated into the vitreous cavity. (Khirurgiya podvyvikhnutogo i vyvikhnutogo v steklovidnoe telo khrustalika.) Cheboksary: GOU IUV. 2007; 11–13. (In Russ.)

Supplementary files

Supplementary Files
Action
1. JATS XML

© 2019 Kopaev S.Y., Il´inskaya I.A., Burtseva A.A.

Creative Commons License

This work is licensed
under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.





Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».