Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty


Cite item

Abstract

Introduction. The matter of the replacement of acetabular defects is becoming increasingly relevant today. In their clinic the authors used custom-made implants with trabecular coating for replacement of defects in the acetabulum where and when it was necessary to ensure extended fixation of the component. Purpose — to evaluate short-term clinical and functional outcomes, osteointegration of porous coated custom-made implants, the overall survival of structural components and to identify the causes of failures and complications. Materials and Methods. During the study the authors interviewed and evaluated radiographs of 48 patients operated from October 2015 to June 2018. The patients were interviewed before and after the surgery using the Oxford hip joint scale, quality of life EQ-5D and visual analogue pain scale. Radiographs were evaluated for a period of at least 12 months for the signs of osteointegration. Results. The average OHS scores increased from 14.9 (±7) to 37.6 (±7) (p<0.01). Quality of life according to the EQ-5D index increased from 0.2 (±0.2) to 0.7 (±0.2) (p<0.01). The average value by general health scales: before operations — 49 (±17) and 73 (±18) scores after surgeries (p<0.01). The average VAS pain score decreased from 73 (±10) to 19 (±19) points (p<0.01). Osteointegration was observed in 98 percent of cases. Migration of the implant with fracture of a flange was observed in one case. Conclusions. In the short-term follow up the use of custom-made implants significantly improves hip joint function and the patients’ life quality. Custom-made implants enable primary reliable fixation in case of complex acetabular defects. High rate of osteointegration is observed for custom-made implants with porous coating within at least 12 months. Longer follow-up is needed to evaluate long-term results.

About the authors

A. N. Kovalenko

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru

Cand. Sci. (Med.), Researcher

St. Petersburg

Russian Federation

A. A. Dzhavadov

Vreden Russian Research Institute of Traumatology and Orthopedics

Author for correspondence.
Email: alisagib.dzhavadov@mail.ru

Research Assistant

St. Petersburg

Russian Federation

I. I. Shubnyakov

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru

Chief Researcher

St. Petersburg

Russian Federation

S. S. Bilyk

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru

Research Assistant

St. Petersburg

Russian Federation

A. O. Denisov

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru

Cand. Sci. (Med.), Academic Secretary

St. Petersburg

Russian Federation

M. A. Cherkasov

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru

Cand. Sci. (Med.), Orthopedic Surgeon

St. Petersburg

Russian Federation

A. I. Midaev

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru

Clinical Resident

St. Petersburg

Russian Federation

R. M. Tikhilov

Vreden Russian Research Institute of Traumatology and Orthopedics,
Mechnikov North-Western State Medical University

Email: fake@neicon.ru

Dr. Sci. (Med.), Professor, Director; professor, Traumatology and Orthopedics Department

St. Petersburg

Russian Federation

References

  1. Gwam С.U., Mistry J.B., Mohamed N.S., Thomas M., Bigart K.S., Mont M.A., Delanois R.E. Current epidemiology of revision total hip arthroplasty in the United States: National Inpatient Sample 2009 to 2013. J Arthroplasty. 2017;32(7):2088-2092. doi: 10.1016/j.arth.2017.02.046.
  2. Patel A., Pavlou G., Mújica-Mota R.E., Toms A.D. The epidemiology of revision total knee and hip arthroplasty in England and Wales: a comparative analysis with projections for the United States. A study using the National Joint Registry dataset. J Bone Joint. 2015; 97-B(8):1076-1081. doi: 10.1302/0301-620X.97B8.35170.
  3. Kowalik T.D., DeHart M., Gehling H., Gehling P., Schabel K., Duwelius P., Mirza A. The Epidemiology of Primary and Revision Total Hip Arthroplasty in Teaching and Nonteaching Hospitals in the United States. J Am Acad Orthop Surg. 2016;24(6):393-398. doi: 10.5435/ JAAO S-D-15-00596.
  4. Yoon P.W., Lee Y.K., Ahn J., Jang E.J., Kim Y., Kwak H.S. et al. Epidemiology of hip replacements in Korea from 2007 to 2011. J Korean Med Sci. 2014;29(6):852-858. doi: 10.3346/jkms.2014.29.6.852.
  5. J afari S.M., Coyle C., Mortazavi S.M., Sharkey P.F., Parvizi J. Revision hip arthroplasty: infection is the most common cause of failure. Clin Orthop Relat Res. 2010;468(8):2046-2051. doi: 10.1007/s11999-010-1251-6.
  6. Bozic K.J., Kamath A.F., Ong K., Lau E., Kurtz S., Chan V. et al. Comparative Epidemiology of Revision Arthroplasty: Failed THA Poses Greater Clinical and Economic Burdens Than Failed TKA. Clin Orthop Relat Res. 2015;473(6);2131-2138. doi: 10.1007/s11999-014-4078-8.
  7. Badarudeen S., Shu A.C., Ong K.L., Baykal D., Lau E., Malkani A.L. Complications after revision total hip arthroplasty in the medicare population. J Arthroplasty. 2017;32(6):1954-1958. doi: 10.1016/j.arth.2017.01.037.
  8. Migaud H., Common H., Girard J., Huten D., Putman S. Acetabular reconstruction using porous metallic material in complex revision total hip arthroplasty: A systematic review. Orthop Traumatol Surg Res. 2019;105(1S):S53-61. doi: 10.1016/j.otsr.2018.04.030.
  9. Taunton, M.J., Fehring, T.K., Edwards P., Bernasek T., Holt G.E., Christie M.J. Pelvic Discontinuity Treated With Custom Triflange Component. Clin Orthop Relat Res. 2012;470(2):428-434. doi: 10.1007/s11999-011-2126-1.
  10. Мурылев В.Ю., Петров Н.В., Рукин Я.А., Елизаров П.М., Калашник А. Д. Ревизионное эндопротезирование вертлужного компонента эндопротеза тазобедренного сустава. Кафедра травматологии и ортопедии. 2012;(1):20-25.
  11. C hristie M.J., Barrington S.A., Brinson M.F., Ruhling M.E., DeBoer D.K. Bridging massive acetabular defects with the triflange cup: 2- to 9-year results. Clin Orthop Relat Res. 2001;(393):216-227. doi: 10.1097/00003086-200112000-00024.
  12. Волокитина Е.А., Хабиб М.С.С. Эндопротезирование тазобедренного сустава при деформациях и дефектах вертлужной впадины (обзор литературы). Уральский медицинский журнал. 2018;(1):56-63.
  13. Holt G.E., Dennis D.A. Use of custom triflanged acetabular components in revision total hip arthroplasty. Clin Orthop Relat Res. 2004;429:209-214. doi: 10.1097/01.blo.0000150252.19780.74.
  14. C itak M., Kochsiek L., Gehrke T., Haasper C., Suero E.M., Mau H. Preliminary results of a 3D-printed acetabular component in the management of extensive defects. Hip Int. 2018;28(3):266-271. doi: 10.5301/hipint.5000561.
  15. Kieser D.C., Ailabouni R., Kieser S.C.J., Wyatt M.C., Armour P.C., Coates M.H., Hooper G.J. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up. Hip Int. 2018;28(6):668 - 674. doi: 10.1177/1120700018760817.
  16. Martino I.D., Strigelli V., Cacciola G., Gu A., Bostrom M.P., Sculco P.K. Survivorship and Clinical Outcomes of Custom Triflange Acetabular Componentsin Revision Total Hip Arthroplasty: A Systematic Review J Arthroplasty. 2019. pii: S0883-5403(19)30515-7. doi: 10.1016/j.arth.2019.05.032.
  17. Telleria J.J., Gee O.A. Classifications In Brief: Paprosky Classification of Acetabular Bone Loss. Clin Orthop Relat Res. 2013;471(11):3725-3730. doi: 10.1007/s11999-013-3264-4.
  18. Тихилов Р.М., Шубняков И.И., Денисов А.О. Классификации дефектов вертлужной впадины: дают ли они объективную картину сложности ревизионного эндопротезирования тазобедренного сустава? (критический обзор литературы и собственных наблюдений). Травматология и ортопедия России. 2019;25(1):122-141. doi: 10.21823/2311-2905-2019-25-1-122-141.
  19. Yu R., Hofstaetter J.G., Sullivan T., Costi K., Howie D.W., Solomon L.B. Validity and reliability of the Paprosky acetabular defect classification. Clin Orthop Relat Res. 2013;471(7):2259-2265. doi: 10.1007/s11999-013-2844-7.
  20. Gozzard С., Blom A., Taylor А., Smith E., Learmonth I. A comparison of the reliability and validity of bone stock loss classification systems used for revision hip surgery. J Arthroplasty. 2003;18(5):638-642. doi: 10.1016/s0883-5403(03)00107-4.
  21. Nilsdotter А., Bremander A. Measures of Hip Function and Symptoms: Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOO S), Oxford Hip Score (OHS), Lequesne Index of Severity for Osteoarthritis of the Hip (LISOH), and American Academy of Orthopedic Surgeons (AAO S). Arthritis Care Res (Hoboken). 2011; 63(Suppl 11):S200-207. doi: 10.1002/acr.20549.
  22. Judge A., Arden N.K., Kiran A., Price A., Javaid M.K., Beard D. et al. Interpretation of patient-reported outcomes for hip and knee replacement surgery: identification of thresholds associated with satisfaction with surgery. J Bone Joint Surg Br. 2012;94(3):412-418. doi: 10.1302/0301-620X.94B3.27425.
  23. Mancuso C.A., Salvati E.A., Johanson N.A., Peterson M.G., Charlson M.E. Patients› expectations and satisfaction with total hip arthroplasty. J Arthroplasty. 1997;12(4): 387-396. doi: 10.1016/s0883-5403(97)90194-7.
  24. Moore M.S., McAuley J.P., Young A.M., Engh C.A. Radiographic Signs of Osseointegration in Porous-coated Acetabular Components. Clin Orthop Relat Res. 2006;444: 176-183. doi: 10.1097/01.blo.0000201149.14078.50.
  25. Тихилов Р.М., Шубняков И.И., Коваленко А.Н., Билык С.С., Цыбин А.В., Денисов А.О., Дмитревич Г.Д., Вопиловский П.Н. Применение индивидуальной трехфланцевой конструкции при ревизионном эдопротезировании с нарушением целостности тазового кольца (клинический случай). Травматология и ортопедия России. 2016;(1):108-116. doi: 10.21823/2311-2905-2016-0-1-108-116.
  26. Корыткин А.А., Захарова Д.В., Новикова Я.С., Горбатов Р.О., Ковалдов К.А., Эль Мудни Ю.М. Опыт применения индивидуальных трехфланцевых вертлужных компонентов при ревизионном эндопротезировании тазобедренного сустава. Травматология и ортопедия России. 2017;23(4):101-111. doi: 10.21823/2311-2905-2017-23-4-101-111.
  27. Kavalerskiy G.M., Murylev V.Y., Rukin Y.A., Elizarov P.M., Lychagin A.V., Tselisheva E.Y. Three-dimensional models in planning of revision hip arthroplasty with complex acetabular defects. Indian J Orthop. 2018;52(6):625-630. doi: 10.4103/ortho.IJO rtho_556_16.
  28. Volpin A., Konan S., Biz C., Tansey R.J., Haddad F.S. Reconstruction of failed acetabular component in the presence of severe acetabular bone loss: a systematic review. Musculoskelet Surg. 2019;103(1):1-13. doi: 10.1007/s12306-018-0539-7.
  29. Issa S-P., Biau D., Babinet A., Dumaine V., Hanneur М.L., Anract P. Pelvic reconstructions following peri-acetabular bone tumour resections using a cementless ice-cream cone prosthesis with dual mobility cup. Int Orthop. 2018;42(8):1987-1997. doi: 10.1007/s00264-018-3785-2.
  30. F isher N.E., Patton J.T., Grimer R.J., Porter D., Jeys L., Tillman R.M. et al. Ice-cream cone reconstruction of the pelvis: a new type of pelvic replacement. J Bone Joint Surg Br. 2011;93(5):684-688. doi: 10.1302/0301-620X.93B5.25608.
  31. Glas P.Y., Béjui-Hugues J., Carret J.P. [Total hip arthroplasty after treatment of acetabular fracture]. Rev Chir Orthop Reparatrice Appar Mot. 2005;91(2):124-131. (in French).
  32. Paprosky W., Muir J. Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accu racy during total hip arthroplasty. Med Devices (Auckl). 2016;9:401-408. doi: 10.2147/MDER.S119161.
  33. Baauw M., van Hellemondt G.G., van Hooff M.L., Spruit M. The accuracy of positioning of a custommade implant within a large acetabular defect at revision arthroplasty of the hip. Bone Joint J. 2015;97-B(6):780-785. doi: 10.1302/0301-620X.97B6.35129.
  34. Коваленко А.Н., Тихилов Р.М., Билык С.С, Шубняков И.И., Черкасов М.А., Денисов А.О. Позиционирование индивидуальных вертлужных компонентов при ревизиях тазобедренного сустава: действительно ли они подходят как «ключ к замку»? Вестник травматологии и ортопедии им. Н.Н. Приорова. 2017;(4): 31-37. doi: 10.32414/0869-8678-2017-4-31-37.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2023 Traumatology and Orthopedics of Russia

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».