Evaluation of the effectiveness of single session audiovisual stimulation for the organism functional state’s correction


Cite item

Full Text

Abstract

Based on the analysis of the changes in the bioelectrical activity of the brain, the dynamics of cerebral blood flow and the vegetative balance of the body, the efficacy of a single 15-minute session of audiovisual stimulation for the correction of the functional state of the organism was evaluated. It was found that after the audiovisual stimulation session, the mean value of the alpha-rhythm power in the frontal, anterior-parietal and occipital leads of the right and left hemispheres of the brain was statistically significant more than in the background study. Such a change in the power of the alpha-rhythm reflects the level of ascending activation necessary for the organization of adaptive behavior, and can also characterize the intensity of the neuro-emotional stress. Increasing the power of the α-rhythm indicates a decrease in the level of nonspecific cerebral activation and is one of the main characteristics of the state of functional comfort. Statistically significant ifferences in the indices of powers of the β - and β -rhythms inherent in the state of active wakefulness were determined. The decrease1 2in the power index of the electoencephalography delta rhythm was revealed. The revealed dynamics of cerebral blood flow parameters was subject to pronounced individual differences, which made it impossible to determine the direction of the trend. It was established a gradual decrease in the power of the low-frequency component of the cardiorhythm with simultaneous increase in the contribution power of the high-frequency component, reaching a statistically significant difference at the last stage of registration, which leads to a significant decrease in the coefficient of vagosympathetic balance after the audiovisual stimulation session. The revealed changes indicate a decrease in the tone of the sympathetic part of the autonomic nervous system. Thus, it is established that after a single 15-minute audiovisual stimulation session, the value of the α-rhythm power in the frontal, anterior parietal and occipital leads of the right and left hemispheres of the brain increases, the power indices of the beta and delta rhythms of the electoencephalography decrease, the stress index and the vegetative index decrease balance, and also the coefficient of the vagosympathetic balance of the rhythmocardiogram. These changes characterize the optimization of the functional state of the organism and contribute to an accelerated restoration of working capacity.

About the authors

V N Sysoev

Военно-медицинская академия им. С.М. Кирова

Email: vmeda-nio@mil.ru
Санкт-Петербург

A V Chebykina

Военно-медицинская академия им. С.М. Кирова

Email: vmeda-nio@mil.ru
Санкт-Петербург

M A Dushkina

Военно-медицинская академия им. С.М. Кирова

Email: vmeda-nio@mil.ru
Санкт-Петербург

V B Dergachev

Военно-медицинская академия им. С.М. Кирова

Email: vmeda-nio@mil.ru
Санкт-Петербург

References

  1. Араби, Л.С. Применение светозвуковой стимуляции в пси- хосоматической клинике / Л.С. Араби, В.Н. Сысоев, В.В. Гайворонская // Международная академия. Межакадеми- ческий информационный бюллетень. - 2011. - № 46. - С. 244-248.
  2. Максимов, О.Б. Аудиовизуальная коррекция дезадаптивных нервно-психических состояний у корабельных специали- стов: автореф. дис. … канд. мед. наук / О.Б. Максимов. - СПб.: ВМА, 2007. - 17 с.
  3. Максимов, О.Б. Эффективность применения аудиовизу- ального воздействия с помощью комплекса «Мираж» для коррекции функционального состояния у корабельных специалистов в плавании / О.Б. Максимов, В.Н. Сысоев // Актуальные проблемы теории и практики социально- правовой защиты и медико-психологической коррекции: мат. научн.-практ. конф. - СЗФ ВНИИ МВД РФ, МИРВЧ. - 2006. - С. 60-62.
  4. Павленко, С.С Аудиовизуальная стимуляция в лечении дли- тельных головных болей: тез. докл. научно-практического семинара «Аудиовизуальная стимуляция и ее применение в медицине» / С.С. Павленко, О.В. Филатова. - Новосибирск, 1996. - 18 с.
  5. Половникова, Л.В. Использование аппарата «Вояджер» в психотерапевтической работе с сотрудниками УВД: тез. докл. научно-практического семинара «Аудиовизуальная стимуляция и ее применение в медицине» / Л.В. Половни- кова. - Новосибирск, 1996. - 22 с.
  6. Семке, В.Я. Применение аудиовизуальной стимуляции в комплексной терапии пограничных нервно-психических расстройств: тез. докл. конф. НИИ психического здоровья ТНЦ СО РАМН / В.Я. Семке и др. - Томск, 1996. - 23 с.
  7. Сысоев, В.Н. Аудиовизуальная стимуляция в комплексной терапии психогенно обусловленных расстройств / В.Н. Сысоев, Л.С. Араби, Т.В. Кремнева // Вестн. психотерапии. - 2011. - № 39 (44). - С. 9-17.
  8. Сысоев, В.Н. Бинауральная синхронизация работы полушарий мозга как эффективный способ коррекции функциональ- ного состояния организма военнослужащих / В.Н. Сысоев, С.Э. Асташко, А.Ю. Чудаков // Вестн. Росс. воен.-мед. акад. - 2007. - Прилож. № 3 (19). - С. 56-61.
  9. Шаров, Р.А. Использование аудиовизуальной стимуляции для оптимизации военно-профессиональной адаптации курсантов военного вуза: автореф. дис. … канд. мед. наук / Р.А. Шаров. - СПб.: ВМА, 2009. - 21 с.
  10. Anderson, D.J. The treatment of migraine with variable frequency photo-stimulation / D.J. Anderson // Headache. - 1989. - Vol. 29, № 3. - P. 154-155.
  11. Kumano, H. Treatment of a depressive disorder patient with EEG- driven photic stimulation / Н. Kumano [et al.] // Biofeedback Self. Regul. - 1996. - Vol. 21, № 4 - P. 323-334.
  12. Richardson, A. The effects of photic stimulation and private self- consciousness on the complexity of visual imagination imagery / А. Richardson A., F. McAndrew // British J. of Psychology. - 1990. - № 81. - P. 381-394.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2018 Sysoev V.N., Chebykina A.V., Dushkina M.A., Dergachev V.B.

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».