Draft Tubes of Water Turbines in Underground and Semi-Underground Powerhouses


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The effect of the centerline radius, bend angle, and diffuser length of high draft tubes in underground and semi-underground powerhouses on head losses is studied analytically. It is established that the dependence of the head losses on the diffuser length does not depend on the capacity, flow rate, and runner diameter of the water turbine; therefore, the diffuser length should be consistent with the construction conditions, but no greater than 35 – 40 m. The centerline radius r0 of the elbow increases with its bend angle α.

Sobre autores

I. Mikhailov

Moscow State University of Civil Engineering

Autor responsável pela correspondência
Email: orexov-gv@mail.ru
Rússia, Moscow

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Springer Science+Business Media, LLC, part of Springer Nature, 2018