Radiodiagnosis of peptic ulcer with technetium-99m-labeled esomeprazole


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Esomeprazole was labeled with 99mTc in high (up to ~98.0%) radiochemical yield. The optimum conditions are as follows: pH 8, 50 μg of SnCl2·2H2O, 30 min, and 2 mg of the substrate. The complex is stable for 8 h. The reaction mixture was separated by gel chromatography using such eluents as NaCl solution and, phosphate, citrate, and carbonate buffer solutions. Free 99mTcO4 and the complex were also efficiently separated by reversed-phase HPLC, paper chromatography, and electrophoreses. Intravenous biodistribution studies of 99mTc-esomeprazole complex showed high uptake in the stomach ulcer, reaching about 30.5% ID/g at 1 h post injection. Such a high 99mTc-esomeprazole uptake makes this agent promising for stomach ulcer imaging.

作者简介

M. Sanad

Labeled Compounds Department, Radioisotopes Production and Radioactive Sources Division, Hot Laboratories Center

编辑信件的主要联系方式.
Email: drsanad74@gmail.com
埃及, Cairo

H. Talaat

Labeled Compounds Department, Radioisotopes Production and Radioactive Sources Division, Hot Laboratories Center

Email: drsanad74@gmail.com
埃及, Cairo

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Inc., 2017