Determination of concentrations of fission products by ICP–AES in solutions from spent nuclear fuel reprocessing


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

A procedure was developed for determining the gravimetric concentration of U and fission products (Ba, Mo, Zr, Sr, Rb, Pd, and Cd) in solutions from spent nuclear fuel (SNF) reprocessing, using inductively coupled plasma atomic emission spectrometry (ICP–AES). The optimum analysis parameters were found. The analytical lines that are not significantly affected by the matrix element were chosen for the elements being determined. The total margin of error in measurements of the metal concentrations (0.1–2500 mg L–1) by the suggested procedure is in the interval 1–20% (for the minimal concentration). The detection thresholds of uranium fission products in model solutions at optimum parameters vary in the interval from 0.020 to 0.1 mg L–1.

Sobre autores

Yu. Naumova

Khlopin Radium Institute

Autor responsável pela correspondência
Email: Y.A.Naumova@khlopin.ru
Rússia, 2-i Murinskii pr. 28, St. Petersburg, 194021

N. Sapozhnikova

Khlopin Radium Institute

Email: Y.A.Naumova@khlopin.ru
Rússia, 2-i Murinskii pr. 28, St. Petersburg, 194021

O. Egorova

Khlopin Radium Institute

Email: Y.A.Naumova@khlopin.ru
Rússia, 2-i Murinskii pr. 28, St. Petersburg, 194021

A. Lumpov

Khlopin Radium Institute

Email: Y.A.Naumova@khlopin.ru
Rússia, 2-i Murinskii pr. 28, St. Petersburg, 194021

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Pleiades Publishing, Inc., 2017