Noise of electrode sensor in pulsating liquid flow


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A periodic component of the ac electrode voltage (electrode noise) is revealed in experiments. The frequency of the periodic component is equal to the pulsation frequency of the flow velocity of liquid in which the electrode sensor is immersed. For the electrode sensor that moves in liquid such a component of the electrode noise may prevail and determine the sensitivity. The sensitivity of a sensor with stainless-steel electrodes with respect to the velocity pulsations is determined to be 1.2 × 10−6 V s/m. Pulsations of the electrode potential can be interpreted using variations in the rate of electrochemical reaction on the electrode surface.

作者简介

V. Maksimenko

Kotel’nikov Institute of Radio Engineering and Electronics (Fryazino Branch)

编辑信件的主要联系方式.
Email: max54@ms.ire.rssi.ru
俄罗斯联邦, Fryazino, Moscow oblast, 141190

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Inc., 2017