Critical Flow of Liquid in a Long Channel


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The results of experimental investigation of critical flow of liquid nitrogen in a long adiabatic channel are presented. As the experimental specimen a channel with a length of 1646 mm, and an inner diameter of 4 mm was used. Pressure in the experiments at the inlet to the specimen was changed in the range pin = (3.06–5.39) × 105 Pa, the outlet pressure was pout = (1.26–4.44) × 105 Pa, and the volumetric flow rate was in the range V = (0–0.042) × 10–3 m3/s. The calculation of the coordinate of the cross section, in which one should expect the emergence of a shock wave, has been conducted. The calculation of local values of speed of sound and the velocity of the mixture allowed us to determine the critical value of the volumetric vapor quality in the critical cross section. Quantitative comparison of the conditions of emergence and existence of the critical flow in the long channel in comparison with short channels is carried out. Fundamental differences are shown.

作者简介

A. Sudarchikov

National Research University “Moscow Power Engineering Institute”

编辑信件的主要联系方式.
Email: SudarchikovAM@mail.ru
俄罗斯联邦, Moscow, 111250

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2018