Determining Displacements of Pulsed Electromagnetic Source of Seismic Signals
- 作者: Ivashin V.V.1, Pevchev V.P.1
-
隶属关系:
- Tolyatti State University
- 期: 卷 54, 编号 4 (2018)
- 页面: 575-581
- 栏目: Science of Mining Machines
- URL: https://ogarev-online.ru/1062-7391/article/view/184541
- DOI: https://doi.org/10.1134/S1062739118044038
- ID: 184541
如何引用文章
详细
The technology for nonexplosive seismic exploration of oil and gas reservoirs uses pulsed electromagnetic sources of seismic signals. Aiming to improve the technology efficiency, it is suggested to upgrade control in order to properly adjust the equipment operation mode. As a control parameter, the absolute displacement of the seismic source is chosen. This parameter is determined by estimating displacement of armature relative induction coil in electromagnetic motor. In the pulsed seismic source, it is difficult to apply displacement sensors with power drive as well as remote control sensors for the determination of movement of elements in the electromagnetic motor. The analysis of electromechanical transformation of energy in the electromagnetic motor of a seismic source shows indirect determination capability of the required parameter by means of measurement of electric values in the power system: armature current and magnetic flux though the gap.
作者简介
V. Ivashin
Tolyatti State University
Email: V.Pevchev@tltsu.ru
俄罗斯联邦, Tolyatti, 445020
V. Pevchev
Tolyatti State University
编辑信件的主要联系方式.
Email: V.Pevchev@tltsu.ru
俄罗斯联邦, Tolyatti, 445020
补充文件