Symmetry of Arc Furnace Operation
- Authors: Shurygin Y.A.1
-
Affiliations:
- Lipetsk State Technical University
- Issue: Vol 47, No 11 (2017)
- Pages: 732-736
- Section: Article
- URL: https://ogarev-online.ru/0967-0912/article/view/179866
- DOI: https://doi.org/10.3103/S0967091217110110
- ID: 179866
Cite item
Abstract
The electrical asymmetry in the operation of arc furnace with an asymmetric triangular configuration of the electrodes is noted. Experimental data from the DSP-100 furnace permit analysis of how the electrical parameters affect the arc characteristics. Nonuniform power distribution over the phases of the electrofurnace decreases the component of the useful power consumed in heating the metal and slag. The power consumption by the furnace may potentially be reduced by 7.4% and the electrode consumption by 9%. The results confirm the need for research on phase-by-phase regulation of the power of ac arc furnaces.
About the authors
Yu. A. Shurygin
Lipetsk State Technical University
Author for correspondence.
Email: shurygin_86@mail.ru
Russian Federation, Lipetsk