Evaluation of Functional and Biomechanical Properties of Bone Regenerates
- 作者: Schurov V.A.1, Mesnard M.2
-
隶属关系:
- Ilizarov Research Center for Rehabilitating Traumatology and Orthopedics
- Institute de Méchanique et d’Ingénierie
- 期: 卷 44, 编号 1 (2018)
- 页面: 77-82
- 栏目: Article
- URL: https://ogarev-online.ru/0362-1197/article/view/177527
- DOI: https://doi.org/10.1134/S0362119718010164
- ID: 177527
如何引用文章
详细
Functional tests with incrementing axial load on the affected limb were performed in patients with humerus, tibia and fibula fractures, or undergoing tibial bone lengthening using the Ilizarov apparatus (n = 75). It was found that oossification was associated with a decrease in the blood flow velocity in the arteries of the bone regenerate. In the humerus, the exercise tolerance was two to three times lower, while the micromotion rate of bone fragments and the blood flow velocity were higher. The micromotion rate and the blood flow velocity decreased by the end of the fixation period, since they were no longer affected by the incrementing load.
作者简介
V. Schurov
Ilizarov Research Center for Rehabilitating Traumatology and Orthopedics
编辑信件的主要联系方式.
Email: shchurovland@mail.ru
俄罗斯联邦, Kurgan
M. Mesnard
Institute de Méchanique et d’Ingénierie
Email: shchurovland@mail.ru
法国, Bordeaux
补充文件