Investigation of a LYSO crystal for a low-energy calorimeter
- 作者: Djilkibaev R.M.1
-
隶属关系:
- Institute for Nuclear Research
- 期: 卷 60, 编号 3 (2017)
- 页面: 330-335
- 栏目: Nuclear Experimental Technique
- URL: https://ogarev-online.ru/0020-4412/article/view/159718
- DOI: https://doi.org/10.1134/S0020441217030058
- ID: 159718
如何引用文章
详细
The results of studying a calorimeter cell in the low-energy region, ~50 MeV, which consists of a LYSO crystal and two avalanche photodiodes, are presented. The use of two photodiodes per crystal made it possible to perform a preliminary measurement of the calorimeter energy resolution using one calorimeter cell and cosmic muons. The coefficient of the stochastic contribution to the calorimeter energy resolution and the crystal luminescence time were measured (0.115% and 50 ns, respectively).
作者简介
R. Djilkibaev
Institute for Nuclear Research
编辑信件的主要联系方式.
Email: rmd@inr.ru
俄罗斯联邦, Moscow, 117312