Investigation of the Hydrodynamic Flow Pattern in Tubular Membrane Devices


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The present work examines the hydrodynamic flow pattern in an industrial tubular baromembrane device on the example of commercially available membrane elements at pressures of 1.0–4.0 MPa. Experimental response curves and dependence curves of the longitudinal mixing coefficient were obtained as a function of the solution flow rate and the pressure in the membrane module. Based on this information, the criterial equation for calculating the longitudinal mixing coefficient was obtained. Numerical values of empirical coefficients are given, which can theoretically be used to calculate the longitudinal mixing coefficients as well as to predict the values for similar constructions of baromembrane systems operating at high transmembrane pressures.