Conditions of Stable Ignition of Coal-Water Slurry Containing Petrochemicals Based on Carbon Residue of Tire Pyrolysis


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The results of experimental investigations of ignition of single droplets (radius of 0.5–1.5 mm) of coal-water slurry containing petrochemicals (CWSP) in a stream of air (oxidizer) with a temperature of 600–1200 K and velocity of 0.5–5 m/sec are presented. Carbon residue (particle sizes of 80–100 μm) from pyrolysis of used automobile tires, water, and exhausted engine, turbine and transformer oils were used as the main fuel components. The times of ignition delay and complete combustion of CWSP droplets were determined atvarying concentrations of the components in the ranges corresponding to modern combustion and burner devices. The conditions at which stable combustion of CWSP is initiated were determined.

Sobre autores

K. Vershinina

National Research Tomsk Polytechnic University

Autor responsável pela correspondência
Email: pavelspa@tpu.ru
Rússia, Tomsk

D. Glushkov

National Research Tomsk Polytechnic University

Email: pavelspa@tpu.ru
Rússia, Tomsk

P. Strizhak

National Research Tomsk Polytechnic University

Email: pavelspa@tpu.ru
Rússia, Tomsk

D. Shabardin

National Research Tomsk Polytechnic University

Email: pavelspa@tpu.ru
Rússia, Tomsk

Arquivos suplementares

Arquivos suplementares
Ação