Control of Hemodialysis Therapy Based on the Bioelectrical Impedance Analysis


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The Diamant-AIST device (Diamant Ltd., St. Petersburg, Russia) was used to assess the body composition and the nutritional status in hemodialysis patients. The obtained results were used for a prospective study of the correlation between patient survival and the results of the bioelectrical impendance analysis. A statistically significant difference in the overall survival and the survival of cardiovascular patients was shown to exist between patients with high and low body fat.