Use of Ion Beam Modification and Gas-Thermal Oxidation in the Process of Formation of Structurally Heterogeneous Oxide Coatings for Titanium Medical Implants
- Авторлар: Rodionov I.V.1, Perinskaya I.V.1, Kuts L.E.1, Perinskii V.V.1, Egorov I.S.1, Fomin A.A.1
-
Мекемелер:
- Yuri Gagarin State Technical University of Saratov
- Шығарылым: Том 51, № 5 (2018)
- Беттер: 303-307
- Бөлім: Theory and Design
- URL: https://ogarev-online.ru/0006-3398/article/view/235226
- DOI: https://doi.org/10.1007/s10527-018-9736-9
- ID: 235226
Дәйексөз келтіру
Аннотация
A new promising method for preliminary ion beam processing of titanium implants has been suggested and tested. The method uses high-energy Не+ ion implantation to achieve a high level of open porosity needed to form thin-layered coatings by the method of gas-thermal oxidation in air. The mechanism of pore formation and the effect of the obtained structurally heterogeneous oxide coatings on the osteointegration of rod implants are described.
Авторлар туралы
I. Rodionov
Yuri Gagarin State Technical University of Saratov
Email: afominalex@rambler.ru
Ресей, Saratov
I. Perinskaya
Yuri Gagarin State Technical University of Saratov
Email: afominalex@rambler.ru
Ресей, Saratov
L. Kuts
Yuri Gagarin State Technical University of Saratov
Email: afominalex@rambler.ru
Ресей, Saratov
V. Perinskii
Yuri Gagarin State Technical University of Saratov
Email: afominalex@rambler.ru
Ресей, Saratov
I. Egorov
Yuri Gagarin State Technical University of Saratov
Email: afominalex@rambler.ru
Ресей, Saratov
A. Fomin
Yuri Gagarin State Technical University of Saratov
Хат алмасуға жауапты Автор.
Email: afominalex@rambler.ru
Ресей, Saratov
Қосымша файлдар